Hisense RS-11DC4S Service Manual page 7

Single door serial

Advertisement

NO COOLING
The compressor
doesn't run
Poor running of
the compressor
The compressor
runs
Refrigerator (freezer)
Check if the current flows at the
contacting point of the thermostat
Check the current flowing of
starting system
Check if the current flows at the
main coil of the compressor
Check the components on the main
circuit
Measure the starting voltage
Check if the current flows at the
contacting point of the starting
system
Check if the current flowing of the
sub coil of the compressor
Is the current amount of the
electric components normal
Frost doesn't form at the
evaporator when operating set for
more than 30min
Poor contacting point
Shorted broken
Coil shorted
Low voltage
Poor contacting point
and broken
Shorted
The coil of the
compressor motor is
worn out
Refrigerant leaks poor
compressing
7
Service manual
Replace the thermostat
Replace the device
Replace the
compressor
Replace the
components
Increase the voltage
Replace the device
Replace the
compressor
Replace the
compressor
Repair the compressor
Single door serial