3.Refrigeration system diagram
when the refrigerator is just powered on. The refrigerant flows in the sequence: Compressor
Condenser
4.Circuit diagram
The thermostat directly controls the start and stop of compressor and hence the refrigerator temperature. The
door switch directly controls the start and stop of the lamp.
Refrigerator (freezer)
Dry filter
Capillary tube
Evaporator.
5
Service manual
Single door serial