Download Print this page

Sony MVC-FD100H Service Manual page 86

Digital still camera
Hide thumbs Also See for MVC-FD100H:

Advertisement

MVC-FD100/FD100H/FD200/FD200H
1-6.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1. Battery Down Adjustment
Set the battery end voltage.
If the voltage is incorrect, the life of battery will shorten.
The image at the battery end will also be rough.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Connection:
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-28.
Preparations before adjustment:
1) Adjust the output voltage of the regulated power supply so
that the digital voltmeter display is 6.1 ± 0.1 Vdc.
2) Turn on the HOLD switch of the adjusting remote commander.
3) Turn on the power supply.
4) Set the CAMERA mode.
Regulated power supply
5.55 ± 0.01 Vdc
CAMERA
Arbitrary
Displayed data of page: 2,
address: 52
Adjusting remote commander
D
90 to 94
Digital voltmeter
Adjusting method:
Order Page Address Data
1
0
01
2
3
2
52
4
D
90
5
6
7
8
D
91
9
D
92
10
D
93
11
D
94
Note: Refer to table 5-2-2 "Hexadecimal-decimal conversion
table".
Processing after Completing Adjustments:
Order Page Address Data
1
0
01
Power cord
(J-6082-223-A)
Fig. 5-1-28
5-42
Procedure
01
Decrease the output voltage
of the regulated power supply
so that digital voltmeter
display is 5.55 ± 0.01 Vdc.
Read the data and this data is
named Dref
Dref Press PAUSE button.
Convert Dref to decimal
notation and obtain Dref'.
(Note)
Calculate D
', D
', D
91
92
93
D
'using following equa-
94
tions (decimal calculation).
D
'= Dref' + 5
91
D
'= Dref' + 23
92
D
'= Dref' + 44
93
D
'= Dref' + 55
94
Convert D
', D
', D
'and
91
92
93
D
'to a hexadecimal number,
94
and obtain D
, D
, D
91
92
93
D
. (Note)
94
D
Press PAUSE button.
91
D
Press PAUSE button.
92
D
Press PAUSE button.
93
D
Press PAUSE button.
94