RS 1319A Instruction Manual

Digital thermometer

Advertisement

RS
DIGITAL THERMOMETER
1319A
INSTRUCTION MANUAL
C
F
MX
MN AVG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1319A and is the answer not in the manual?

Questions and answers

Summary of Contents for RS 1319A

  • Page 1 DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL MN AVG...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TITLE PAGE 1. INTRODUCTION ............1 2. SPECIFICATIONS............1 3. NAME OF PARTS AND POSITIONS......3 4. OPERATION INSTRUCTIONS ........5 5. OPEN THERMOCOUPLE INDICATION ..... 7 6. RECALIBRATION PROCEDURE ....... 7 7. MAINTENANCE ............7...
  • Page 3: Introduction

    1. INTRODUCTION This instrument is a digital thermometer for use with any K- type thermocouple as a temperature sensor. Temperature indication follows the international temperature scale of 1990. (ITS-90) Read the following information carefully before attempting to operate or service the meter. When servicing, use only specified replacement parts.
  • Page 4 NOTE This basic accuracy specification does not include the error of the temperature probe. Please refer to the probe accuracy specification for additional details. Temperature coefficient: 0.1 × specified accuracy / per °C at 0°C to 18°C & 28°C to 40°C. Input Protection : 20V maximum input voltage.
  • Page 5: Name Of Parts And Positions

    3. NAME OF PARTS AND POSITIONS MN AVG...
  • Page 6 LCD Display : a). Main display : Temperature reading. b). Secondary display : Temperature MAX, MIN, AVG reading and offset reference value. c). Memory display : 1 ~ 150 sets. d). Auto power off mark (P). HOLD key : Press H HOLD key to freeze or unfreeze the display reading.
  • Page 7: Operation Instructions

    4. OPERATION INSTRUCTIONS WARNING To avoid electrical shock or personal injury, do not apply more than 20Vrms, between the thermocouple input, or between thermocouple and earth ground. 4-1 Temperature Measurement Press " " key to turn on the thermometer. Plug the thermocouple into the thermocouple input. If no thermocouple plugged into...
  • Page 8 4-3 To Trigger "One by One Datalogging" and Clear Stored Data Press "MEM" key each time, stores one set logged reading in memory, LCD will show " MEM " and memory location numbers (1 to 150). Press "READ" key to enter the reading memory data mode.
  • Page 9: Open Thermocouple Indication

    2. If the thermocouple connected to the input is broken or open-circuit. 6. RECALIBRATION PROCEDURE The thermometer should be calibrated once a year to ensure its continued accuracy. Contact RS Components for further details of calibration service. The address is given at the end of these instructions. 7. MAINTENANCE...