TEST AND MEASUREMENT
6.5.1 Ramping Gain
The carrier power must be measured and calibrated for each power level at channel 62.
GSM 900
Power Level
PL5
PL6
PL7
PL8
PL9
PL10
PL11
PL12
PL13
PL14
PL15
PL16
PL17
PL18
PL19
GSM 1800
Power Level
PL0
PL1
PL2
PL3
PL4
PL5
PL6
PL7
PL8
PL9
PL10
PL11
PL12
PL13
PL14
PL15
Issue 1
Revision 0
Peak Power
Tolerance
(dBm)
(dBm)
32.4
+0.3, -0.6
30.7
±0.5
29
±0.5
27
±0.5
25
±0.5
23
±0.5
21
±0.5
19
±0.5
17
±0.5
15
±0.5
13
±0.5
11
±0.5
9
±0.5
7
±0.5
5
±0.5
Peak Power
Tolerance
(dBm)
(dBm)
29.3
+0.4, -0.5
27.7
±0.5
26
±0.5
24
±0.5
22
±0.5
20
±0.5
18
±0.5
16
±0.5
14
±0.5
12
±0.5
10
±0.5
8
±0.5
6
±0.5
4
±0.5
2
±0.5
0
±0.5
Section 6
– 38 –
Initial
Change per
Calibration
dB
Value
214
7.0
200
5.0
190
4.5
181
4.0
173
5.0
163
5.0
153
4.5
144
3.5
137
3.5
130
2.5
125
2.5
120
3.0
114
3.5
107
3.5
100
3.5
Initial
Change per
Calibration
dB
Value
194
5.0
184
4.0
176
4.0
168
4.5
159
4.0
151
3.5
144
3.5
137
3.5
130
2.5
125
3.0
119
2.5
114
2.5
109
3.0
103
3.0
97
2.5
92
2.5
MCUK991001C8
Service Manual