this appliance is not connected to a fume exhaust device. It shall be installed in accordance with current installation
regulations. Particular attention shall be given to the relevant requirements regarding ventilation.
-
combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans.
GAS CONNECTION
This operation must be performed by a qualified technician.
WARNING
The gas supply system must comply with local regulations.
You can find specific local regulations for some countries in the paragraph
"Reference to Local Regulations". If no information concerning your Country
is given, please ask details to your Installer.
The connection of the hob to the gas pipe network or gas cylinder must be
made by means of a rigid copper or steel pipe with fittings complying with
local regulations, or by means of a continuous-surface stainless steel hose
complying with local regulations. Interpose gasket (B) in the elbow
connection.The maximum length of the hose is 2 m.
FOR BELGIUM ONLY: It is necessary to replace the elbow connection (A) on
the appliance, with the one supplied (if present).
IMPORTANT: if a stainless steel hose is used, it must be installed so as not to
touch any mobile part of the furniture. It must pass through an area where
there are no obstructions and where it is possible to inspect it on all its
length.
After connection to the gas supply, check for leaks with soapy water. Light
up the burners and turn the knobs from max position
position
to check flame stability.
ELECTRICAL CONNECTION
This operation must be performed by a qualified technician.
WARNING
The electrical connections must comply
WARNING
with local regulations.
The earthing of this appliance is
compulsory by law.
Do not use an extension cord.
IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.
ASSEMBLY
After having cleaned the perimeter surface,
apply the supplied gasket to the hob as shown
in the figure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.
NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and
fasten them by means of their screws in accordance with the thickness of the worktop (see the following figures).
to minimum
L
Earth
(yellow/green)
N
Top 20 mm
ADJUSTMENT TO DIFFERENT TYPES OF GAS
This operation must be performed by a qualified technician.
WARNING
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label
on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction.
The gas nozzles must be changed by After Sales Service or a qualified technician.
Nozzles not supplied with the appliance must be ordered from After Sales Service.
Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will
go.
IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for
the replacement of the burner tap if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
Remove grids (A).
Extract burners (B).
Using a socket spanner of the appropriate size unscrew
the injector (C), unscrew the injector to be replaced.
Replace it with the injector suitable for the new type of
gas.
Re-assemble the injector in (D).
If you have a multiple crown burner use side spanner to
replace the injector (E).
Before installing the hob, remember to affix the gas
calibration plate supplied with the injectors in such a way
that it covers the existing information relating to gas
calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and
proceed as follows:
tighten screw to reduce the flame height (-);
loosen screw to increase the flame height (+).
The adjustment must be performed with the tap in minimum gas setting position (small
flame) .
The primary air of the burners does not need to be adjusted.
At this stage, light up the burners and turn the knobs from max position
minimum position
to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.