7. Fan Motor Drive Circuit

• For the point A , 15.7 kHz PWM pulse will be output from
the pin N N N N N on the micro computer as shown in Fig. 7-2.
The pulse range will vary with different command speed.
• The pulse is converted into the analog voltage by the
R751 and C751 and applied to the fan motor as the speed
command voltage.
Fig. 7-3 shows the relation between the voltage at the
point B and the speed. (Some differences will occur
due to the condition of the unit.)
• The fan motor outputs the feedback pulse of the speed,
which is input into the pin D D D D D on the micro computer. This
pulse is equivalent to a frequency of 12/60 speed.
(Example: 1000 min-1 x 12/60 = 200 Hz)
The micro computer monitors the frequency and adjusts
the output pulse range of the pin N N N N N so as to keep the
command speed.
• If the feedback pulse is 100 min-1 or less due to a locked fan motor or failure, the fan output will be
stopped temporarily as fan lock error. After 10 seconds, restart the output of the pulse. If fan lock
error is detected twice within 30 minutes, all units are stopped and the unit will come in the failure
mode. (The timer lamp will blink 10 times.)
Micro computer
A
DC fan
24
motor output
R751
DC fan motor
Speed
14
feedback
C
0V
Voltage at point A
Waveform
T2
T1
Voltage at point B
Waveform
T1
Voltage at point C
Waveform
T2
35V
0V
5V
B
C751
0V
R631
C631
Fig. 7-1
Fig. 7-2
– 34 –
CN10
M
Fan motor
Voltage at point B (V)
Fig. 7-3