LG AMNH076LQL0 Service Manual page 183

Multi type air conditioner
Hide thumbs Also See for AMNH076LQL0:
Table of Contents

Advertisement

I Error Indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
LED01G
2 Times
(RED)
1 sec
1 Times
LED02G
(GREEN)
2 sec
Error
Descriotion
code
21
DC Peak (IPM Fault)
22
CT 2(Max CT)
23
DC Link Low Volt.
24
L/H press SW
25
Low voltage / Over voltage
-
-
65
Heatsink Th Error (Open/Short)
67
Outdoor BLDC Fan Lock
105
Comm. Error
(Main board <->Fan board)
Outdoor Error
Ex) Error 26(DC Comp position Error)
LED03G
2 Times
(Yellow)
1 sec
Error
Descriotion
code
21
DC PEAK (IPM Fault)
DC Comp position Error
26
(No Position / Locking) Error
Comm. Error
52
(Main micon <-> Sub micom)
23
DC Link Low voltage Error
40
CT Sensor Open/Short Error
60
A/D Option Error
29
Comp over current Error
2 Times
2 Times
1 sec
1 sec
1Times
1Times
2 sec
LED01G
(Red)
2 times
2 times
2 times
2 times
2 times
-
6 times
6 times
10 times
2 Times
2 Times
1 sec
LED03G
(Yellow)
1 times
2 times
3 times
5 times
6 times
7 times
8 times
LED02G
Indoor
(Green)
Status
1 time
Off
2 times
Off
3 times
Off
4 times
Off
5 times
Off
-
-
5 times
Off
7 times
Off
5 times
Off
Error Display
Time
25 sec
25 sec
25 sec
25 sec
-
-
25 sec
Troubleshooting Guide
Service Manual 183

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents