Download Print this page

HEIL CCA9 Installation Instructions Manual page 4

R−410a two−stage split system air conditioner

Advertisement

INSTALLATION INSTRUCTIONS
Accessory
Crankcase Heater
Compressor Start Assist Capacitor and Relay
Liquid Line Solenoid Valve
Support Feet
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Long Line Applications Guideline.
Table 2 − Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (In.)
UNIT SIZE
724
924
736, 936
748, 948
760, 960
* Units are rated with 25 ft. (7.6 m) of lineset. See Specification sheet for performance data when using different size and length linesets.
Notes:
1. Do not apply capillary tube or fixed orifice indoor coils to these units.
2. For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 35 ft. (10.7 m) vertical differential 250 ft. (76.2 m) Total Equivalent Length),
refer to the Long Line Applications Guideline.
Use of the AHRI Certified
TM Mark indicates a
manufacturer's
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
4
Table 1 − Accessory Usage
REQUIRED FOR LONG LINE
APPLICATIONS* (Over 80 ft. / 24.38 m)
Yes, standard on some units
Yes
See Long Line Applications Guideline
No
LIQUID
Connection and Tube
Diameter
3/8
3/8
3/8
3/8
3/8
ISO 9001:2000
REGISTERED
R−410A Split System Air Conditioner
Required for Sea Coast Application
(within 2 miles/3.22 km)
RATED VAPOR
up to 80 ft. (24.38 m)*
Connection
Diameter
3/4
7/8
7/8
7/8
7/8
This product has been designed and manufactured to meet
Energy Star® criteria for energy efficiency when matched
with appropriate coil components. However, proper
refrigerant charge and proper air flow are critical to achieve
rated capacity and efficiency. Installation of this product
should follow all manufacturing refrigerant charging and air
flow instructions. Failure to confirm proper charge and
air flow may reduce energy efficiency and shorten
equipment life.
No
No
No
Recommended
Rated Tube
Diameter
3/4
7/8
7/8
1−1/8
1−1/8
421 01 1701 00