ACCESSORIES
REFRIGERANT CIRCUIT ACCESSORIES
- Electronic thermostatic valve;
- Condensing pressure controlled by operation circuit regulator with low external temperatures;
- Double set point (high/low temperature) with a single electronic expansion valve. The evaporator is
sized according to high temperature operation. The set point can be changed from the keyboard or
the digital input, in this case must be specified in the order;
- High and low pressure switches are available for all models;
- Fluid receptors (supplied as standard for HP, HP/LE and DC, DC/LE versions);
- Intake and delivery valves on compressor line;
- Solenoid valve on fluid line (supplied as standard for HP and HP/LE and LE versions);
- Low water temperature kit.
HYDRAULIC CIRCUIT ACCESSORIES
- Defroster for the evaporator (the ST version is equipped with an antifreeze resistance on the tank,
piping system and on the pump spiral, which is insulated for this reason) and on any recovery heat
exchanger;
- Water side safety valve (ST version only). The valve calibration value is 6 bar, which corresponds to
the maximum allowed operating pressure.
ELECTRICAL ACCESSORIES
- Serial interface RS485 suited for Carel and Modbus protocols;
- Power factor correction cos ⱷ ≥ 0.9 under nominal operating conditions; on the external board in IP
55 (power supply connected by the installer directly on the main). The accessory is combined with
dry contacts;
- Remote user terminal (in addition to the standard one);
- Dry contacts.
MISCELLANEOUS ACCESSORIES
- Rubber antivibration mounts;
- Copper/copper condensation coil;
- Copper/tinned-copper condensation coil;
- Prepainted aluminium condensation coil;
- Condensation coil with passivated aluminium and polyurethane coating.
The treatment consists of a double layer, the first of which passivates the aluminium and acts as a
primer and the second which is a polyurethane-based surface coating. The product has high anti-
corrosive properties and virtually resists to all environmental conditions. For installation in marine
and rural environments, from industrial to urban areas;
- Packaging in wooden crates;
- Special pallet/skid for container shipment;
- Non-standard "RAL" paint colours.
DOUBLE SET-POINT
The microprocessor enables you to set two set temperatures for the production of cold and hot water.
Unless specified otherwise in the order, the default values are 12/7°C and 15/10°C for chiller mode
and 40/45°C and 35/40°C for heat pump mode. The set temperatures must, in any case, remain within
the operating ranges of the unit.
Use either the keypad or the digital input to switch between the first and second set. For series that do
not permit the simultaneous selection of "Select summer/winter mode with digital input" and "Double
set point with digital input", summer/winter mode can be selected only on the keypad while the double
set point still uses the digital input, as per our standard.