5. Turn the MIX controller (9) on the Lehle Parallel M all the way to the right, so that you have 100 %
of the original signal on the output.
6. Use the Send controller (8) on the Lehle Parallel M to set the optimum output level.
7. Done!
Note:
The signal present on the Send socket (3) is not
electrically isolated from the output. Ground loops
may thus occur and cause undesirable back-
ground noise. In this case, a Lehle P-Split II,
Signal flow chart of the Lehle Parallel M
18
which electrically isolates the signals via its built-in
LTHZ-transformer, and thus eliminates all
background noise, can be connected between the
units.