Kenwood TK-8102 Service Manual page 28

Uhf fm transceiver
Hide thumbs Also See for TK-8102:
Table of Contents

Advertisement

TK-8102
Use KPG-70D programming software for adjustment of the next items.
PCB Section
Item
1. Setting
1) Power supply voltage
DC Power supply teriminal:13.6V
2. VCO lock
1) CH: TX high
voltage
2) CH: RX high
3) CH: TX low
4) CH: RX low
3. IF Coil
1) CH: RX center wide
2) SSG output: -53dBm(501uV)
Mod: 1kHz, Dev: 3kHz
4. RF Band-
1) CH: RX center wide
pass filter
CH: RX low wide
CH: RX high wide
2) Tra generator output: -30dBm
Connect the spectrum analyzer
to BPF terminal
Receiver Section
Item
1. Sensitivity
1) CH: RX low:
CH: RX center:
CH: RX high:
2) SSG output:
-118dBm(0.28µV):
-116dBm(0.35µV):
Mod: 1kHz
Dev: ±3.0kHz: Wide
Dev: ±1.5kHz: Narrow
2. Squelch 9
1) CH: RX low:
CH: RX center:
CH: RX high:
2) SSG output:
9dB above to 12dB SINAD level:
Wide/Narrow
Mod: 1kHz
Dev: ±3.0kHz: Wide
Dev: ±1.5kHz: Narrow
3. Squelch 1
1) CH: RX low:
CH: RX center:
CH: RX high:
2) SSG output:
2dB above to 12dB SINAD level:
Wide/Narrow
Mod: 1kHz
Dev: ±3.0kHz: Wide
Dev: ±1.5kHz: Narrow
Test frequency(MHz)
Channel
TX
1: Center
470.100
2: Low
450.100
3: High
489.900
4
470.000
5
470.200
6
470.400
TK-260
:K, K2
28
ADJUSTMENT
Measurement
Condition
Test equipment
Digital voltmeter
SSG
Digital voltmeter
Tra generator
Spectrum analyzer
Measurement
Condition
Test equipment
Wide/Narrow
SSG
Oscilloscope
Wide/Narrow
AF. V. M
Wide/Narrow
Distortion meter
Wide
Narrow
Wide
Wide/Narrow
Wide
Wide
Wide/Narrow
Wide
RX
470.050
450.050
489.950
470.000
470.200
470.400
Adjustment
Terminal
Parts
Method
CV
TC2
5.5V
TC1
5.5V
Check
AFV
L22
3.2~3.3V(DC)
ANT
TC3
Adjust the BPF waveform to Fig.1
BPF
TC5
Adjustment
Terminal
Parts
Method
ANT
Check
Ext. SP
PC key
Adjust to open the squelch.
Specifications/
Remarks
±0.1V
±0.1V
0.8V or more
Specifications/
Remarks
SINAD:
12dB or higher