Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Water Inlet
The water flows into the regeneration dosage chamber (7) via inlet valve (1), over air break (2),
into regeneration dosage chambers (3) into softener (8). At this point the water divides. 1/4 of
the water enters the tub through the vent (23). 3/4 of the water enters the sump (24) through
hose (6).
The level control chamber built into the sump operates the pressure switch (15).
3
2
4
1
5
6
12
1
Inlet valve
2
Air break
3
Regeneration water dosage
4
Overflow safety level
5
Safety overflow
6
Inlet to sump from regeneration dosage
chamber
7
Regeneration dosage chamber
8
Softener
9
Salt container
10
Non-return valve salt container
11
Regeneration valve
12
Safety inlet hose
04.99
HV 83-N
7
23
11
8
9
10
22
21
24
21
15
16
13
Base tray
14
Float switch
15
Pressure switch
16
Filter
17
Circulation pump
18
Flow heater
19
Drain pump
20
Non-return valve
21
Spray arms
22
Roof-mounted shower
23
Tub vent
24
Sump assembly
292 1372 13