Injectors; Electrodes; Insulation - Baxi Combi Instant 80 HE Installation & Servicing Instructions Manual

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Electrodes

Electrode
Grommets
Electrode
Leads
Side Insulation
Combustion Box
Door
(Instant 105 HE
model shown)
Fig. 53
Injector
Manifold
Injector
Burner
Fig. 52
Rear Insulation
Side Insulation
Front Insulation
12.0
Inlet Elbow
12.5
1. Remove the burner as described in Section 12.4.
2. Undo the screws securing the injector manifold to
the inlet elbow and remove the manifold.
Gasket
3. Unscrew and replace injectors as required and
examine the sealing gasket, replacing as necessary.
Reassemble in reverse order.
12.6
1. Remove the four screws securing the combustion
box door and remove the door.
2. Undo the screws securing the burner to the injector
manifold. Draw the burner out of the combustion box,
pulling the electrode grommets from the slots in the
combustion box lower panel.
3. Disconnect the lead and grommet from the
electrode being replaced. Undo the securing screw
and withdraw the electrode to the burner.
4. Reassemble in reverse order.
12.7
1. Remove the four screws securing the combustion
box door and remove the door.
2. Slide the side insulation pieces carefully out of their
carriers.
3. To replace the rear insulation piece it is necessary to
remove the heat exchanger as described in Section
12.3 and slide out the side pieces.
4. The combustion box door insulation piece can be
replaced by carefully bending up the two retaining tabs.
5. Replace all insulation pieces and reassemble in
reverse order.
13.8
Changing Components
Injectors (Fig. 52)
Electrodes (Fig. 52)
Insulation (Fig. 53)
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combi instant 105 he

Table of Contents