Alignment And Adjustments - Samsung M1912 Service Manual

Table of Contents

Advertisement

5. Alignment and Adjustments

1. High voltage is present at the high voltage terminal of the high voltage transformer during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components, or wiring, always unplug the oven from its power source and discharge the high voltage
capacitor.
5-1 High Voltage Transformer
1. Remove connectors from the transformer
terminals and check continuity.
2. Normal resistance readings should be as
follows:
Secondary
Filament
Primary
(Room temperature = 20˚C)
5-2 Magnetron
1. Continuity checks can only indicate an open
filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron.
2. Isolate the magnetron from the circuit by
disconnecting its leads.
3. A continuity check across the magnetron filament
terminals should indicate one ohm or less.
4. A continuity check between each filament terminal
and the magnetron case should read "open".
5-1
PRECAUTION
Approx.
100Ω
Approx.0Ω
Approx.1.450Ω
Filament Terminals
Primary
Terminals
Wave Guide
Antenna
Secondary Terminal
Gasket Plate
Magnetron
Samsung Electronics

Advertisement

Table of Contents
loading

Table of Contents