Download Print this page

Alignment And Adjustments - Samsung M183STR Service Manual

Advertisement

5. Alignment and Adjustments

1. High voltage is present at the high voltage terminals during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components or wiring, always unplug the oven from its power source and
discharge the high voltage capacitor.
5-1 High Voltage Transformer
1. Remove connectors from the transformer terminals
and check continuity.
2. Normal resistance readings are as follows:
Secondary
108 Ω ± 10%
Filament
Shows Continuity
Primary
0.453 Ω ± 10%
(Room temperature = 20° C)
5-2 Low Voltage Transformer
1. The low voltage transformer is located on the
control circuit board.
2. Remove the low voltage transformer from the
PCB Ass'y and check continuity.
3. Normal resistor reading is shown in the table.
5-3 Magnetron
1. Continuity checks can indicate only an open
filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron :
2. Isolate the magnetron from the circuit by
disconnecting its leads.
3. A continuity check across the magnetron filament
terminals should indicate one ohm or less.
4. A continuity check between each filament terminal
and magnetron case should read open.
PRECAUTION
SHV-U820A
Terminals
1~2(Input)
3~4(Output7V)
5~6(Output17V)
- 9 -
Resistance
SLV-4270U
1,201 Ω
4.348 Ω
21.72 Ω

Advertisement

loading