ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y173) to perform the circuit adjustments in this section.
Test Equipment Required: 1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
4-1. SETTING THE SERVICE ADJUSTMENT
MODE
1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a second
of each other:
Display
Channel 5
4-1-1. SERVICE ADJUSTMENT MODE ON
1. The CRT displays the item being adjusted.
Mode
service
Signal
ntsc
Type
vchp
2. Press 1 or 4 on the Remote Commander to select the item.
3. Press 3 or 6 on the Remote Commander to change the data.
4. Press MUTING then ENTER to write into memory.
4-1-2. SERVICE ADJUSTMENT MODE
MEMORY
Mode
Category
service
defl
Signal
ntsc
Type
vchp
00000000
1. Press 8 then ENTER on the Remote Commander to initialize.
Mode
Category
service
defl
Signal
ntsc
Type
vchp
00000000
2. Turn set off then on to exit Service Adjustment Mode.
SECTION 4: CIRCUIT ADJUSTMENTS
Sound Volume +
Display
Item
Category
Item
Data
defl
hsiz
16
00000000
00000000
Display
Item
Item
Data
MUTING
hsiz
16
write
00000000
ENTER
Display
Item
Item
Data
MUTING
hsiz
16
write
00000000
ENTER
Carry out Step 1 when adjusting
IDs 0-7 and when replacing and
adjusting IC002
4-2. MEMORY WRITE CONFIRMATION
METHOD
1. After adjustment, pull out the plug from the AC outlet, then replace
the plug in the AC outlet again.
2. Turn the power switch ON and set to Service Mode.
Power
3. Call the adjusted items again to confi rm they were adjusted.
4-3. REMOTE ADJUSTMENT BUTTONS AND
INDICATORS
MUTING
(Enter into
memory)
1
Disp. (Item up)
2
(Device Item Up)
4
Disp. (Item down)
Green
8
(Initialize)
VOLUME (+)
Red
(Service Mode)
Green
Red
— 17 —
KV-13FS100/13FS110/14FV300
POWER
(Service Mode)
DISPLAY
(Service Mode)
3
Item
(Data up)
6
Item
(Data down)
5
(Device item
down)
ENTER
(Enter into
memory)
0
(Remove from
memory)
RM-Y173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-14fv300Trinitron kv-13fs110Rm-y173

Table of Contents