PRODUCT SPECIFICATION

Indoor Unit
Outdoor Unit
Power/Current
Refrigerant
Cooling Capacity
Heating Capacity
Noise Level
Air Circulation
Product Weight
kg
Dimensions (H x W x D)
Test conditions
1.
Temperature (°C)
COOLING
HEATING
2. Standard piping length: 7.5 m (Includes Indoor Unit piping length).
68
Model
[kW]
[A]
[kg]
[kW]
[kW]
JIS C 9612
[<70 dB(A)]
Conditions
[dB(A)]
1m Distance
Max. cooling/
heating
operation
Sound power
[dB(A)]
level
3
[m
/min.]
[kg]
[mm]
Indoor
*DBT
*WBT
27
20
CS-YE9MKE
CU-YE9MKE
COOL
HEAT
Single, 230V,50Hz
0.760
0.880
3.60
4.10
R410A
0.780
2.50
3.20
40
40
47
48
56
56
63
64
12.5
13.0
8.0
22
283 x 803 x 214
540 x 780 x 289
Outdoor
*DBT
19
35
12
7
CS-YE12MKE
CU-YE12MKE
COOL
HEAT
COOL
Single, 230V,50Hz
Single, 230V,50Hz
1.020
1.105
1.660
4.90
5.20
7.90
R410A
0.880
3.30
4.00
42
42
46
48
50
50
58
58
62
64
66
66
13.5
13.9
14.6
8.0
26.5
283 x 803 x 214
283 x 803 x 214
540 x 780 x 289
540 x 780 x 289
*WBT
24
6
CS-YE18MKE
CU-YE18MKE
HEAT
1.615
7.70
R410A
1.15
5.00
5.50
46
52
62
68
15.3
7.5
31.5

Hide quick links: