SAFETY / LISTING LABEL
MODEL
Portland
US
Report No. 050-S-07b-5
LISTED VENTED GAS FIREPLACE HEATER - FIREPLACE INSERT - NOT FOR USE WITH SOLID FUEL
TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 "VENTED GAS FIREPLACE HEATERS", CSA P.4.1-02, AND CGA 2.17-M91.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI
Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING
FIREPLACES ONLY - MASONRY OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE
COMBUSTION AND VENTILATION AIR.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. SEE OWNER'S MANUAL FOR
DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT,
FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USE) OR CSA C22-1-LATEST EDITION (CANADA).
RATINGS
NG
Maximum Input BTU/hr 0-2000 Ft. (0-610 M)*
39,000 39,000 Minimum Inlet Pressure (IN. WC)
Minimum Input BTU/hr 0-2000 Ft. (0-610 M)*
27,500 22,600 Manifold Pressure - HI (IN. WC/C.E.)
Orifice (DMS)*
#33
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M
ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
CHIMNEY-USE WITH B-VENT CHIMNEY OR SINGLE WALL GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY
1,000 FT (405 M).
WARNING: OPERATION OF THIS APPLIANCE WHEN NOT CONNECTED TO A PROPERLY INSTALLED AND MAINTAINED
VENTING SYSTEM OR TAMPERING WITH THE BLOCKED VENT SHUTOFF SYSTEM CAN RESULT IN CARBON MONOXIDE (CO)
POISONING AND POSSIBLE DEATH.
MINIMUM FIREPLACE SIZES REQUIRED
29.75" Front Opening
19.00" Opening Height
19.00" Rear Width
15.25" Fireplace Depth
INSERT HEARTH PROTECTION - Non-Combustible Hearth Extension
G = Minimum Hearth Protection
G
23"
G =
Distance from Fireplace Facing
H = Vertical Distance from Insert
H
0"
H =
Bottom* to Combustible Material
Note: Hearth protection to be min. 3/8" (10mm) thick non-combustible or
equivalent, with a k factor of .84.
* Insert bottom is the metal lip below the lower gold trim bar.
CLEARANCES TO COMBUSTIBLES
A = 14.5" to Top Facing (max thickness 3/4")
B = 24" to Mantel** (more than 3/4")
C = 6.5" to Side Facing (3/4" or less)
D = 11" to Side Wall
E = 24" to Mantel**, more than 3/4"
F = 14-1/2" to Top Facing, maximum thickness 3/4"
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS
AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING
INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS
APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED
INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.
DATE OF MANUFACTURE
2010 2011 2012 2013
2007
2008
2009
2010 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
DO NOT REMOVE OR COVER THIS LABEL
Part No. 36226 Rev. C, 3/2010
FIRESTAR™
SERIAL
INSERT/GC3
NO.
FACTORY EQUIPPED FOR
Manufactured by:
LENNOX HEARTH PRODUCTS
NATURAL GAS. IF CONTROL PANEL
PO BOX 987
CONTRADICTS THIS LABEL, UNIT
AUBURN, WA 98071 USA
FUEL TYPE HAS BEEN CONVERTED.
LP
#49
Manifold Pressure - LO (IN. WC/C.E.)
MINIMUM CLEARANCES
Mantel
E**
Trim
20"
17"
0"
C
2"
4"
6"
D
G
Hearth / Floor Protection
** The minimum distance from the top of the insert to a
combustible may be reduced to 16" with a mantel shield. See
installation and operation manual for shield dimensions.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Portland
US
Número de Rapport 050-S-07b-5
FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
AUBURN, WA., USA 98071
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS UTILISER AVEC
DU COMBUSTIBLE SOLIDE
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», CSA P.4.1-02, ET CGA 2.17-M91.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D'INSTALLATION
ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE
INSTALLÉ SELON LES DIRECTIVES D'INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE
SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N'EST PAS
CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LES TYPES DE GAZ INDIQUÉS SUR LA PLAQUE SIGNALÉTIQUE. CET
APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L'USAGE AVEC D'AUTRES TYPES DE GAZ À MOINS D'UTILISER UNE TROUSSE
DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L'APPAREIL AVANT D'EN FAIRE L'ENTRETIEN.
SI L'APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE
CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D'INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
NG
LP
SPÉCIFICATIONS
5
10.5
Entrée Maximum BTU/hr 0-4500 Pi (0-1370 M)* 39,000 39,000 Pression Minimum D'entrée Du Gaz (IN. WC/C.E.)
3.5
10
Entrée Minimum BTU/hr 0-4500 Pi (0-1370 M)* 27,500 22,600 Pression À La Sortie - HI (IN. WC/C.E.)
1.7
3.5
Orifice (DMS)*
*EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L'APPAREIL DIMINUE
DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES
RÉFÉREZ-VOUS AU MANUEL D'INSTRUCTIONS DU PROPRIÉTAIRE POUR CHANGER LE BLOC D'ASSEMBLAGE DE LA VALVE.
CHEMINÉE - ÉVACUATION :INSTALLER AVEC DE L'ÉVENT À GAZ DE TYPE B-VENT OU UN CONDUIT FLEXIBLE À SIMPLE
PAROI HOMOLOGUÉ COMME TUBAGE.
CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D'ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D'INSTALLATION DU
FABRICANT.
AVERTISSEMENT : UTILISER CET APPAREIL AVEC UN SYSTÈME DE VENTILATION INADÉQUAT (MAUVAISE INSTALLATION OU
MAUVAIS ENTRETIEN) OU ALTÉRER LE SYSTÈME D'ARRÊT AUTOMATIQUE EN CAS D'UN BLOCAGE D'ÉVENT PEUT CAUSER UN
EMPOISONNEMENT AU MONOXYDE DE CARBONE QUI POURRAIT ENTRAÎNER LA MORT.
DIMENSIONS MINIMUMS DE FOYER REQUISES
A = 29.75" Ouverture avant
B = 19.00" Hauteur
C = 19.00" Largeur arrière
D = 15.25" Profondeur du foyer
F
PROTECTION DU FOYER
G = Extension d'âtre min. devant le foyer
H = Distance verticale de la base
de l'appareil aux combustibles
H
* La base du poêle encastrable est le repli de métal située sous la
plaque de finition dorée.
Note: Extension d'âtre fabriqué avec 3/8" (10mm) minimum de matériaux
non-combustible ou équivalent possédant un facteur k de 0.84.
DIMENSIONS MINIMUMS DE FOYER REQUISES
A = 14.5" (368mm) Ouverture avant
B = 24" (610mm) Hauteur
C = 6.5" (165mm) Largeur arrière
D = 11" (279mm) Profondeur du foyer
E = Dessus du foyer à partir de la base 24" (610mm)
F = Mur latéral à partir du centre du foyer 14.5" (368mm)
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L'ÉCART DES
ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS
LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D'ESSENCE ET AUTRES
VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT
TEMPS. VOIR LES MANUELS D'INSTALLATION ET D'ENTRETIEN QUI ACCOMPAGNENT L'APPAREIL. SEUL LE PANNEAU
VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L'APPAREIL NE
PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ
PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU'UN AJUSTEMENT, UNE MODIFICATION, UNE
RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ.
RÉFÉREZ-VOUS AU MANUEL D'ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L'ASSISTANCE, CONSULTEZ UN
INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.
LA DATE DE FABRICATION EST INDIQUÉE DANS LA SECTION ANGLOPHONE DE CETTE ÉTIQUETTE
Part No./ No. pièce #36266 Rev. B, 03/2010
IGN
SERIAL
Le numéro de série est indiqué dans la
FIRESTAR™
MODÈLE
INSERT/GC3
NO.
section anglophone de cette étiquette
CET APPAREIL EST MUNI D'ÉQUIPEMENT POUR L'USAGE DU GAZ NATUREL. SI
L'ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE ÉTIQUETTE,
C'EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
NG
LP
#33
#49
Pression À La Sortie - LO (IN. WC/C.E.)
MANTEAU
Mantel
DE FOYER
MANTEAU
G
584mm
508mm
432mm
0mm
Trim
PIÈCE DE
FINITION
H
0mm
51mm
102mm
152mm
D
G
** L'espace minimum entre le dessus du poêle
encastrable et les matériaux combustibles peut être
réduit à 16" en utilisant un protecteur de manteau
de cheminée. Consultez le manuel d'installation et
d'entretien pour les dimensions recommandées du
protecteur.
N'ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE
NG
LP
5
10.5
3.5
10
1.7
3.5
DÉGAGEMENTS MINIMUMS
E**
F
C
H
Protection Du Foyer
IGN
25