1-1 Unit Specifications
MODEL No.
POWER SOURCE
PERFORMANCE
Capacity
Air circulation (Hi/Me/Lo)
Moisture removal(High)
External static pressure(High)
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes*
Max. running amperes**
Power input
Power factor
C.O.P
Max. starting amperes
FEATURES
Controls / Thermostat control
Timer
Fan speeds Indoor/Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (drain connection)
Compressor
Operation sound
REFRIGERANT TUBING
Limit of tubing length
Limit of tubing length at shipment
Limit of elevation difference
between the two units
Refrigerant tube
outer diameter
Refrigerant amount at shipment
DIMENSIONS & WEIGHT
Unit dimensions
Package dimensions
Net weight
Shipping weight
Shipping volume
Cooling :
Rating conditions(*) :
Full load conditions(**) Indoor air temperature 35
Heating :
Rating conditions(*) :
Full load conditions(**) Indoor air temperature 24
Indoor Unit
Outdoor Unit
kW
BTU / h
m3 / h
Liters/h
mmAq(Pa)
V
V
A
A
kW
%
W / W
A
Indoor - Hi/Me/Lo
dB - A
Outdoor - Hi
dB - A
m (ft.)
m (ft.)
m (ft.)
Narrow tube
mm (in)
Wide tube
mm (in)
kg
Height
mm (in)
Width
mm (in)
Depth
mm (in)
Height
mm (in)
Width
mm (in)
Depth
mm (in)
kg (lb)
kg (lb)
3
m
(Cu. ft.)
Indoor air temperature 27
Indoor air temperature 20
– 11 –
SPW-U483GH56
SPW-C483GH8
380 - 400 - 415 V / 3N / 50 Hz
Cooling
14
47,800
1,920/1,440/1,200
6.8
7(69) : at shipment, 12(118) : using the booster cable
380
400
415
342 - 456
8.6
8.8
9
9.3
9.3
9.5
4.95
5.16
5.27
87.5
84.6
81.5
2.83
2.71
2.66
71
73
75
Microprocessor / I.C. thermostat
ON / OFF 72-hours
3 and Automatic control/ 2 (Auto)
-
Field supply
Wired:RCS-SH80TG
Electronic Refrigerant Control Valve
Max. head 25cm above drain connection (25A,OD32mm)
Scroll
42 / 36 / 30, (46 / 42 / 38 : using the booster cable)
55
50 (164)
30 (98)
Outdoor unit is higher than indoor unit: 50 (164)
Outdoor unit is lower than indoor unit: 30 (98)
9.52 ( 3 / 8 )
19.05 ( 3 / 4 )
R22 - 4.5
Indoor unit
310 (12-7/32)
1,480 (58-9/32)
665 (26-6/32)
380 (14-31/32)
1,679 (66-3/32)
866 (34-3/32)
64 (141)
71 (157)
0.553 (19.5)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
°
°
C DB / 19
C WB, Outdoor air temperature 35
°
°
C DB / 25
C WB, Outdoor air temperature 45
°
C DB, Outdoor air temperature 7
°
C DB, Outdoor air temperature 24
1. Specifications
1. Specifications
Heating
16
54,600
-
380
400
415
342 - 456
9.2
9.2
9.5
10
9.7
9.4
5.32
5.47
5.58
87.9
85.8
81.7
3.01
2.93
2.87
71
73
75
Outdoor unit
1,235 (48-20/32)
940 (37)
340 (13-12/32)
1,326 (52-7/32)
1,016 (40)
416 (16-12/32)
108 (238)
115 (254)
0.56 (19.8)
°
C DB
°
C DB
°
°
C DB / 6
C DB
°
°
C DB / 15.5
C WB
SM830035
1
1