Plumbing

The machine must be connected to
the water supply in accordance with
local and national regulations.
Disconnect the machine from the
electrical supply before connecting
it to the water supply.
Turn off the water supply before
connecting the coffee machine to
the plumbing.
– All units and systems used to deliver
the water to the coffee system must
conform with the requirements of the
respective country.
– Only connect the machine to the
cold water supply.
– The machine can be connected
without a non-return valve.
– The on-site water line must have a
water shut-off valve to turn the water
off if needed. If not present, have a
water valve installed by a licensed
plumber.
– The water faucet must be accessible
after installation.
– Water pressure on-site:
Minimum: 14.5 psi
Maximum: 145 psi, if higher, install a
pressure reduction valve.
– Suitable 1/4" tubing or copper piping
must be supplied for plumbing.
80
– To ensure the best coffee quality, the
maximum length of the tubing or
copper pipe should not exceed 4 ft.
11" (1.5 m). If too much water
remains in the tubing the coffee
quality could be affected.
Make sure that the shut-off valve is
accessible after the unit has been
installed.
Parts must only be replaced with
original Miele spare parts, available
from Miele.