COLD CLIMATE INSULATION

For cold climate installations, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter the
room. It is especially important to insulate
outside chase cavity between studs and
under floor on which appliance rests, if floor
is above ground level. Gas line holes and
other openings should be caulked or stuffed
with unfaced fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood
or other raised platform can be placed
underneath to prevent cold transfer to the
fireplace and into the room. It also helps
to sheetrock inside surfaces and tape for
maximum air tightness and caulk firestops.
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in
an aftermarket permanently located,
manufactured home and must be installed
in accordance with the manufacturer's
instructions.
Cet appareil peut être installé cómme
du matéri-el d'origine dans une maison
préfabriquée (É.U. seulement) ou mobile
et doit être installé selon les instructions
du fabricant.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
Cet appareil doit être utilisé uniquement
avec le type de gaz indiqué sur la plaque
signalétique. Cet appareil ne peut être
converti à d'autres gaz.
CAUTION: Ensure that the cross
members are not cut or weakened
during installation. The structural
integrity of the manufactured home
floor, wall, and ceiling/roof must
be maintained.
CAUTION: This appliance must
be grounded to the chassis of the
manufactured home in accordance with
local codes or in the absence of local
codes, with the National Electrical
Code ANSI / NFPA 70—latest edition.
DLX POWER VENT DV GAS FIREPLACES (MDLX40/45IN-PV) • INSTALLATION INSTRUCTIONS
®
Room Divider
Application
Recessed
Application
Figure 2: Typical Installation

LOCATION

In selecting the location, the aesthetic and
functional use of the appliance are primary
concerns. However, vent system routing to
the exterior and access to the fuel supply are
also important.
Due to high temperatures, the appliance
should be located out of traffic and away
from furniture and draperies (Figure 2).
En raison des températures élevées,
l'appareil devrait être installé dans
un endroit où il y a peu de circulation
et loin du mobilier et des tentures
(Figure 2).
The location should also be free of
electrical, plumbing or other heating/air
conditioning ducting.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: When the unit is installed with one
side flush with a wall, the wall on the other
side of the unit must not extend beyond the
front edge of the unit.
Horizontal
Drywall
Termination
Fireplace
Top of Fireplace
Opening
Be aware that this is a heat producing
appliance. Objects placed above the unit
are exposed to elevated temperatures.
Do not insulate the space between the
appliance and the area above it.
The appliance must be mounted on a
fully supported base extending the full
width and depth of the unit. The appliance
may be located on or near conventional
construction materials. However, if installed
on combustible materials, such as carpeting,
vinyl tile, or other combustible material other
than wood flooring, the appliance shall be
installed on a metal or wood panel extending
the full width and depth of the appliance.
Noncombustible