Thermostat Wiring - Single Stage Heat Pump (With Ygvi Control) - V/S Air Handler - York YZF Installation Manual

Outdoor split-system heat pump 16/18 seer 2 to 5 tons
Table of Contents

Advertisement

835966-UIM-E-0814
C
24 - Volt Common
Y1
First Stage Compressor
R
24 - Volt Hot
G
FAN
Fault
W3
Third Stage Heat
Y2
Second Stage
Compressor
W2
Second Stage Heat
W1/O/B
First Stage Heat
HUM
(only on S1-
THSU32HP7b)
DHUM
(only on S1-
THSU32HP7b)
Jumper 1 must be
set to "HEAT PUMP"
Jumper 2 must be
set to "O"
Jumper 3 must be
set to "ELEC"
Setup Step 24 "Number
Of Compressor Stages"
must be set "1"
FIGURE 12: Thermostat Wiring – Single Stage Heat Pump (with YGVI control) – V/S Air Handler
12
Single Stage Heat Pump (with YGVI control) - V/S Air Handler
AHV
MV
First Stage Compressor
Open on Humidity Rise
24VAC Humidifier Relay
(Optional)
24VAC Electronic
Air Cleaner Relay
(Optional)
ID MODELS
COM
24 - Volt Common
Y/Y2
Second or Full
Stage Compressor
R
24 - Volt Hot
G
FAN
W1
First Stage Heat
W2
Second Stage Heat
Y1
O
Reversing Valve
Energized In Cool
X/L
Malfunction Light
HUM
Humidity Switch
HUM OUT
(24 VAC out)
Humidifier
EAC
(24 VAC out)
Electronic Air Cleaner
Move the HUM STAT
jumper to "YES"
if humidistat is to be
used.
Refer to AH
documentation
for W1 and W2 electric
heat staging options
C
24 - Volt Common
Y1
Single Stage
Compressor
R
24 - Volt Hot
W1 OUT
First Stage Heat
W2 OUT
Second Stage Heat
Y2 OUT
Second Stage
Compressor
O
Reversing Valve
Energized In Cool
X/L
Malfunction Light
Y2
Second Stage
Compressor
W
Auxiliary Heat
BSG
Bonnet Sensor
BS
Bonnet Sensor
Change "FFuel" jumper
on the heat pump control
to "OFF"
A008-001
Johnson Controls Unitary Products

Hide quick links:

Advertisement

Table of Contents