Yamaha YFM400FAR Service Manual page 119

Hide thumbs Also See for YFM400FAR:
Table of Contents

Advertisement

Charging method using a constant voltage charger
YES
Charge the battery until the charging
voltage reaches 15 V.
NOTE:
Set the charging time to a
maximum of 20 hours.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V
Charging is complete.
12.0 ~ 12.7 V
Recharging is required.
Under 12.0 V
Replace the battery.
CAUTION:
Constant amperage chargers are
not suitable for charging MF
batteries.
CHECKING THE BATTERY
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Voltmeter
3 - 58
CHK
ADJ
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NO
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.
Charger
Ammeter

Advertisement

Table of Contents
loading

Table of Contents