Sony KDP-51WS655 Service Manual page 9

Color rear video projection
Hide thumbs Also See for KDP-51WS655:
Table of Contents

Advertisement

Display of Standby/Timer LED Flash Count
Diagnostic items
+B Overcurrent
Low +B Overvoltage
Vert. Deflection Stopped
White Balance Failure
Low +B OCP/OVP
Horiz. Deflection Stopped
Audio Protection
Zero Crossing Detector
HV Protection
Release of TIMER STAND BY indicator blinking
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the power.
Self-Diagnosis Screen Displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen
disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated or
not) in order to allow confi rmation.
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
Display
Channel 5
SELF DIAGNOSIS
2: +B OCP
3: +B OVP
4: VSTOP
5: AKB
6: LOWB
7: H-STOP
8: AUDIO
9: ZCD
10: HV PROT
101: WDT
Self-Diagnosis Screen Display
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the results
display to " 0 ".
If the results display is not returned to " 0 " it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1. Power off (Set to the stand by mode.)
2. Display
Channel 5
3. Channel 8
ENTER (Test reset = Factory preset condition)
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
KDP-51WS655/57WS655
TIMER Indicator
STAND BY Indicator
Flash count
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
_
Sound Volume*
*Note that this differs from entering the service mode (sound volume + )
0
0
Numeral "0"
0
means that no fault was detected.
1
Numeral "1"
0
means a fault was detected one
time only.
0
0
0
0
24
Sound Volume +
Lamp OFF 3 sec.
Power ON
Power ON (Service Mode)
KDP-51WS655/57WS655
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kdp-57ws655