SOUNDER TEST
WALK TEST
CHIME
9:0 SOUNDER TESTS
It is advisable to check that the sounders are working correctly periodically.
To do this go to a keypad, enter a user code then press * then 9, each of
the tests lasts for 5 seconds.
illuminate, and the system tests start. The lights will go out and the internal
sounder will activate (proceed outside where the external sounder is
fitted). The external sounder will trigger then the external strobe will flash
(if fitted and enabled) and then the panel will clear down. The test is now
complete.
Q
UICK CHECK
Enter code then, *, 9 .
All lights on.
Internal sounder.
External Sounder.
Strobe.
Test Ended Panel clears.
10:0 WALK TESTING
It is advisable to check that the detection devices are communicating with
the panel. This kind of testing should be performed every 3 months. To do
this go to the keypad enter a user code, then press *, then 9 and 4. When
any detector is activated or a door fitted with a contact is opened, the
internal sounder will give a loud pulsing tone and
illuminate. Clear the detector or close the door and the sound will revert
back to a continuous sound, proceed to the next device until you have
completed testing all the zones.
NOTE: The zone LED's will stay on at the keypad until the tests have been
completed to allow confirmation that all zones have operated
correctly.
press * to exit the walk test mode.
Quick check
Enter code then, *, 9 ,4
Walk test the zones
Press * to finish
11:0. CHIME.
The control panel offers the ability to have chime on a zone when unset.
This feature will emit a chime tone via the extension speaker whenever a
zone is activated. To achieve this press the * key and the number key that
represents the zone(s) you want on chime. The light for the zone will
illuminate. Press * to accept the zones on chime. To remove a zone on
chime press the * key and the zones will light up that are currently active.
Press the key that represents the zone, the light will go out, chime is now
disabled on that zone. Press * key to finish. This feature is only active on
zones enabled by your installer.
All the lights on the control panel will
}
EACH CONDITION IN 5 SECOND INTERVALS
Zones that cannot be walk Tested are:
Fire
PA
Tamper
5
the zone light will