Honeywell RedLink Installation Manual page 10

Wireless system with equipment interface module
Hide thumbs Also See for RedLink:
Table of Contents

Advertisement

Available languages

Available languages

RedLINK™ Installation Guide (EIM)
Installer setup tables
Setup functions
15
Compressor off
time (minimum)
16
Schedule format
26
Auxiliary heat
control
27
Maximum heat
setpoint
28
Minimum cool
setpoint
32
Temp. display
offset (indoor)
33
Temp. display
offset (outdoor)
35
Humidity display
offset (outdoor)
Settings & Options
5 5 minutes (Heat On/Cool On flashes during off time)
[Options: 0 to 4 minutes]
Applies only to Model TH6320
0 Weekday/weekend program schedule
1 Weekday/Saturday/Sunday program schedule
Applies only to Model TH5320
0 Comfort
**
1 Economy
90 Max. heat temperature setting is 90°F (32°C)
[Options: 40 to 90°F (4.5 to 32°C)]
50 Min. cool temperature setting is 50°F (10°C)
[Options: 50 to 99°F (10 to 37°C)]
0 Thermostat displays actual temperature
[Options: -3 to +3°F offset (-1.5 to +1.5°C)]
0 Thermostat displays actual temperature
[Options: -5 to +5°F offset (-2.5 to +2.5°C)]
3 Thermostat displays actual humidity
[Other options: 0 = -15%, 1 = -10%, 2 = -5%,
4 = 5%, 5 = 10%, 6 = 15% offset]
10
(factory default in bold)
** See page 11