f A power cord is required to connect the hood to the socket in the ceiling. With
extraction mode flexible ducting is also required.
Exhaust connection  6" (150 mm)

Distance between cooktop and ventilation hood (S)

Provided a larger distance is not given by the manufacturer of the cooktop, fol‐
low the minimum safety distances between a cooktop and the bottom of the
hood.
Please also observe the information contained in the "IMPORTANT SAFETY IN‐
STRUCTIONS" section.
Cooking appliance
Electric/Induction cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop
≤ 43,000 BTU/hr (12.6 W),
no burner > 15,000 BTU/hr (4.5 kW).
Multi-burner gas cooktop
≤ 73,800 BTU/hr (21.6 W),
no burner > 16,500 BTU/hr (4.8 kW)
Multi-burner gas cooktop
> 73,800 BTU/hr (21.6 W),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Single-burner gas cooktop
≤ 20,500 BTU/hr (6 kW)
Single-burner gas cooktop
≤ 27,600 BTU/hr (8.1 kW)
Single-burner gas cooktop
> 27,600 BTU/hr (8.1 kW)
Installation
Minimum distance S
Miele appli‐
Non-Miele ap‐
ance
24" (610 mm)
26" (660 mm)
26" (660 mm)
30" (760 mm)
30" (760 mm)
Not possible
26" (660 mm)
30" (760 mm)
30" (760 mm)
Not possible
pliance