Product Overview The Vykon wireless survey tools are intended to verify Index and validate the deployment and use of the Vykon wireless thermostats on a potential job site. Product Overview Included in this package you will fi nd the following items: VYKONStat Wireless Network Overview •...
Gateway. (VWG). • The maximum non-clear line of sight distance between thermostats for gypsum wall partitions • Vykon recommends using a per fl oor horizontal which may include metal stud framing is a maximum architecture vs. a vertical one. Transmitting from of 50 feet or 15 meters (fig.
Page 4
3 feet or 1 meter is maintained between any Vykon node and any Wi-Fi devices. The recommended maximum number of wireless Maintain a distance of 10 feet or 3 meters or more thermostats per JACE is 30;...
200 full charge cycles. • 100% signal strength indicates that the survey tools are functioning properly. • Contact Vykon for replacement batteries. The survey tools use a custom rechargeable battery type. Survey Considerations: DO NOT USE regular rechargeable batteries for replacement;...
2) Set one of the survey tools at the proposed network directly through the coordinator (VWG or coordinator (VWG or Jace-Driver) and note down the Jace-Driver) without any hops or routes (fig. 9). Fig. 9 Wireless Ther ostat Proposed Wireless Coordinator VWG /Jace-Driver Wireless Survey Tools User Guide VST5000W5028W...
Page 7
Keep in mind that the denser the thermostat clusters are, in terms of proximity and thermostat quantity, the better your network effi ciency will be (fig. 11). Fig. 11 Proposed Wireless Coordinator VWG /Jace-Driver Wireless Ther ostat Wireless Survey Tools User Guide VST5000W5028W...
Page 8
Please note that once a device / node / controller has How would orphan nodes appear in the fi eld and how been assigned a ZigBee address & has joined the active would you allow them to join the ZigBee network ? Wireless Survey Tools User Guide VST5000W5028W...
Page 9
Jace / Coordinator. This is due to the nature of the How Orphan nodes are created in the fi eld. Vykon ZigBee stack in the wireless controllers. Ex.: 2 small buildings are within a few feet of each other.
Page 10
Fig. 14 Proposed location Jace Coordinator Ma i u linear distance covered by a single Jace-Coordinator Fig. 15 Channel 25 Pan ID=10 Proposed location Jace Coordinator Channel 25 Pan ID=20 Proposed location Jace Coordinator Wireless Survey Tools User Guide VST5000W5028W...
NO WARRANTY. Vykon (herein after referred to as wireless thermostat product line and associated “Vykon”) makes no warranty as to the accuracy of or network access point. Please note; future application use of this technical documentation. Any use of the...
Page 12
VYKON 3951 Westerre Parkway, Suite 350 Richmond, VA 23233 Phone: ( 804) 747-4771 Fax: (804) 747-5204 contact@tridium.com www.vykon.com...
Need help?
Do you have a question about the VST5000W5028W and is the answer not in the manual?