11-3. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Block
Adjustment Page
Adjustment Address
Note: The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
.
1
2) Read the YAW data written on repair parts, and named this as
L
.
2
PITCH/YAW Data
P.PP / Y.YY
DSC-H50_ADJ
11
61
0E10, 0E11
t L
YAW data
PITCH data t L
Fig. 6-1-25
11-4. Angular Velocity Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 9, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy)
[Save] button: Saves the previous data (Dp, Dy) in the PC as a
[Load] button: Loads and displays the previous data (Dp, Dy)
• Default file name is as follows:
DSC-H50_D
2) Input the previous data (Dp, Dy) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
3) Input the sensitivity of respective sensors (S
"Preparation" into the screen.
If only either sensor was replaced, give a check to the checkbox
2
for the sensor not replaced at the lower left of the screen.
1
4) Input the PITCH/YAW data of lens (L
tion" into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
Note: In order to get the correct value for the adjustment, it is
necessary to input a decimal point ("period" or "comma")
as same format as windows setting because "Numeric Value
Format" depend on the language. (F:123 456 789,00,
GB:123,456,789.00, D:123.456.789,00)
"Numeric Value Format" setting is available in "Control
Panel"-"Regional and Language Options".
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
6-26
from the SY-201 board.
file.
from the file saved in the PC.
D
DT_xxxxxxxx_yyyymmdd.dat
p
y
Date
USB serial number
Data name
, L
) read at "Prepara-
1
2
, S
) read at
501
502