Wiring Diagram For Setting The Cut-Out Relay; Wiring Diagram For Setting The Voltage Andcurrent Regulators - Fiat 500L Workshop Manual

Fiat 500 1957-73
Hide thumbs Also See for 500L:
Table of Contents

Advertisement

Checking cut-out:
1 Closing voltage:
This test should be carried out at a temperature of
25°±10°C and the regulator should be connected to a
generator test bed as shown in FIG 11:7. The unit should
be operated under no load conditions for between 15 -
18 minutes with the cover installed and with a voltage of
between 16.5 volts for an initial operating temperature of
15-20°C or 15 volts for an initial operating temperature
of 20-35°C. This will enable thermal stabilization of the
unit to be obtained so that the temperature of both the
cut-out shunt windings and the bymetallic springs
increase due to the heat developed by the windings and
reaches the normal operating setting.
Once thermal stabilization has been obtained the
generator should be restarted and the speed gradually
increased so that immediately the test lamp starts to
glow the voltmeter reading may be taken. This will be
the value of the cut-out contact closing voltage.
2 Reverse current:
This check should be carried out at a temperature range
of between 25°±10°C and it is recommended that it is
performed as soon as possible after the closing voltage
test so that the thermal stabilization remains unaltered.
Connect the regulator as shown in FIG 11:8 and
gradually speed up the generator to 4500 rev/min for
approximately 5 minutes. Ensure that the voltmeter reads
at least 14.5 volts and then gradually reduce the generator
speed carefully watching the movement of the ammeter
needle which should at first indicate a charging current
and then gradually move to zero and then to the other side
of the scale to indicate reverse current value. If the
generator speed is reduced further the reverse current
reading will increase to a given value and then suddenly
fall to zero which will indicate that the cut-out contact
has opened. This limit indicates the maximum reverse
current value which should not, under any circumstances,
exceed 16 amps.
During this test, to obtain the maximum reverse
current possible the reduction in generator speed must
not take more than 10 seconds otherwise the battery
voltage will drop excessively.
Checking voltage regulator:
This test should be carried out with the regulator under
half load and at a temperature of 50°± 3°C. Connect the
regulator as shown in FIG 11:9 and operate the regulator
for approximately 30 minutes by supplying a current half
that of regulated current which is 1 6 ±5 amp. Once the
regulator has been brought to the required temperature
stop the generator and start it again, gradually increasing
the speed to a maximum of 4500 rev/min. Adjust the
rheostat for a generator output corresponding to half load
current of 8 ±2 amps. When this generator output has
been set the voltage should be 14.2± .3 volts.
Checking current regulator:
Leave the regulator connected as shown in FIG 11 :10
and this test must be carried out immediately after testing
the half load regulated voltage of the voltage regulator
when connected to a battery. Check that the ammeter
fitted will accommodate a 40 amp deflection: if not a
F500
FIG 11 :9
Wiring diagram for checking the current and
voltage regulators
Key to Fig 11:9
GR Regulator GN 1.1 2.1 6
FIAT D 90.12.16.3
V Voltmeter, 20 V scale (0.5% accuracy)
A Ammeter, 20 A scale (to check voltage regulator) and 40 A
scale (to check current regulator)
B Battery, 50 Ah, fully charged
FIG 11 :10 Wiring diagram for setting the cut-out relay
Key to Fig 11 :10
B
2 V battery
A Ammeter, 20 A scale ( 1 % accuracy)
scale (0.5% accuracy), directly connected to terminals 31—51
P Potentiometer for voltage adjustment, having such a capacity
that the current draw of the cut-out shunt winding does not
cause sensible variations in the voltage readings (voltmeter
under no load)
S Test lamp, with 2 V, 3 W bulb, to signal
opening and closing of contacts
R
Voltage drop resistor, suitable to allow turning on of A with
T open and cut-out contacts open
Setting of instruments before inserting the unit:
minimum (voltmeter reads zero)
(max. resistance)
T
Open
FIG 11:11
Wiring diagram for setting the voltage and
current regulators
Key to Fig 11 :11
GR Regulator assembly GN 1.12.16
G Generator D 90.12.16.3
accuracy)
A Ammeter, 20 Amp. scale (for voltage regulator),
or 40 Amp. scale (for current regulator)
Amps., 3 Ohms
B 50 Amp/h battery, fully charged I Switch
G Generator
R Rheostat, 25 A. 3
B
20 V battery
V Voltmeter, 20 V
R Rheostat, 4
12 A
P At
T Open
R All inserted
V Voltmeter, 20 V scale (0.5%
R Rheostat, 25
117