9-2 Refrigerating Cycle Diagram

9/12K
Indoor Unit
Condenser
�as refrigerant discharged from the compressor is cooled down in the condenser of the outdoor unit by means of thermal emission
and turned into a liquid refrigerant before being sent to the evaporator.
Compressor
It compresses the low-temperature, low-pressure refrigerant to let it flow to the Cycle.
Evaporator
As the liquid refrigerant that has been absorbed via capillary tubes evaporates (from liquid to gas), it absorbs heat from the surround-
ings, thereby cooling the indoor area.
Service Valve
Using a hex wrench, turn the needle valve countercloc�wise to open the valve. It is used for vacuuming, gas drain, refrigerant
injection, refrigerant purge, and indoor-outdoor units connection.
Accumulator
It prevents liquid refrigerant from flowing into the compressor.
(If liquid refrigerant enters the compressor, it becomes overloaded)
9-2