160°C.
b. The heater control circuit of IC604 has the built-in function that the software turns off the heater control automatically if the
heater is not turned ON every a fixed time.
c. When the temperature became over 250°C, the heater control circuit of IC604 is turned off forcedly and system reset (IC604
pin 129 becomes Low) will be executed.
The correspondence readings between temperature measured by thermistor and HEX readings
Temperature
AD value
[C°]
0
252
1
251
2
251
3
251
4
251
5
251
6
251
7
250
8
250
9
250
10
250
11
249
12
249
13
249
14
249
15
248
16
248
17
248
18
248
19
247
20
247
21
247
22
246
23
246
24
246
25
245
26
245
27
245
28
244
29
244
30
243
31
243
32
243
33
242
HEX reading
Temperature
[C°]
FC
84
FB
85
FB
86
FB
87
FB
88
FB
89
FB
90
FA
91
FA
92
FA
93
FA
94
F9
95
F9
96
F9
97
F9
98
F8
99
F8
100
F8
101
F8
102
F7
103
F7
104
F7
105
F6
106
F6
107
F6
108
F5
109
F5
110
F5
111
F4
112
F4
113
F3
114
F3
115
F3
116
F2
117
AD value
HEX reading
Temperature
202
CA
200
C8
199
C7
198
C6
197
C5
196
C4
195
C3
193
C1
192
C0
191
BF
190
BE
188
BC
187
BB
186
BA
184
B8
183
B7
182
B6
181
B5
179
B3
178
B2
177
B1
175
AF
174
AE
173
AD
171
AB
170
AA
168
A8
167
A7
166
A6
164
A4
163
A3
162
A2
160
A0
159
9F
258
AD value
HEX reading
[C°]
168
93
169
92
170
91
171
90
172
89
173
88
174
87
175
86
176
85
177
84
178
83
179
82
180
81
181
80
182
79
183
78
184
77
185
76
186
75
187
74
188
74
189
73
190
72
191
71
192
70
193
69
194
68
195
68
196
67
197
66
198
65
199
64
200
64
201
63
5D
5C
5B
5A
59
58
57
56
55
54
53
52
51
50
4F
4E
4D
4C
4B
4A
4A
49
48
47
46
45
44
44
43
42
41
40
40
3F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-flb852cxs

Table of Contents