Trouble shooting

Trouble shooting
Below we have listed a few probable causes and solutions to which you can refer if
your machine does not function properly.
Basic checks
Make sure you have plenty of fuel
Make sure the fuel tap is on
Make sure the engine-switch is on
Remove spark plug, connect spark plug lead and earth it to the generator. Pull
starter cord gently and look for a spark. If there is no spark, replace spark plug.
Spark plug is OK, but engine still won't start
Check fuel tap filter is clean (make sure there is no spilt fuel present)
Check fuel line is clear
Check carburettor is not blocked
Engine will not start
Clean or replace spark plug
Check ignition system – if faulty, contact your service centre
Check compression – if low, contact your service centre
Check for loose cylinder head – tighten bolts
Check for damaged cylinder head gasket – replace if necessary