Fuel tap
To remove the fuel tap filter, simply undo the cup at the bottom of the fuel tank.
Use a small spanner to remove the tap.
Clean and wash out the filter and cup, and replace.
Cleaning
Clean the housing regularly with a soft cloth, preferably every time it is used. Keep the
air vents free of dust and dirt.
Remove stubborn dirt with a soft rag moistened in soapy water. Do not use any
solvents such as petrol, alcohol, ammonia, etc. as such substances can damage the
plastic parts.
Storage (Long term)
Drain fuel tank, fuel tap, carburettor bowl and carburettor
Pour 1 cup of engine oil into the fuel tank and shake the generator to spread the oil
around the tank. Drain excess oil.
Remove spark plug and pour in 1 spoonful of engine oil, pull the starter cord several
times with the starter switch OFF. Replace spark plug.
Pull on the starter cord until you feel compression and stop.
Clean the generators exterior and casing with rust inhibitor.
Place the generator on flat ground and cover with a clean dry cloth.
Faults
Should a fault occur, e.g. after wear of a part, please contact the service address on the
warranty card. On page 8 of this manual you find an exploded view showing the parts
that can be ordered.
Environment
To prevent damage during transport, the appliance is delivered in solid packaging
which consists largely of reusable material. Therefore please make use of options for
recycling the packaging.
Warranty
Read the terms of warranty on the separate warranty card which is enclosed.
AFTER SALES SUPPORT
800
PGM6003 Ma EN-IRL 1202-15.indd 13
Faulty and/or discarded electrical or electronic apparatus have to be collected at
the appropriate recycling locations.
0203-5142281
GB
13
1800-719901
www.servotool.eu
IRL
WGG-800
2/15/12 9:35 AM

Advertisement

Table of Contents
loading

Table of Contents