Spark Plug Inspection; Air Filter Cleaning - Workzone PGM6003 Product Manual

800w generator
Table of Contents

Advertisement

6 Months or 100 hrs
Clean fuel tap and fuel tank filter. Replace if necessary.
Check fittings and fasteners. Replace if necessary.
12 Months or 300 hrs
Contact a specialized service centre to check the valve clearance.
Check the fan of the cooling system for damage.

Spark plug inspection

Fig. 2
Disconnect the spark plug cap, and remove any dirt from around the spark plug
area.
Remove spark plug (10) with the plug spanner supplied.
Inspect the base of the spark plug. It should be a tan colour.
Measure the gap (distance contact point) with a suitable gauge. The gap should be
0,7 - 0,8 mm. Correct the gap, if necessary, by carefully bending the side electrode.
Replace the spark plug if the electrodes are worn, or if the insulator is cracked or
chipped.
Install the spark plug carefully, by hand, to avoid cross-threading.
Tighten the spark plug to the correct torque: 20 Nm.
Attach the spark plug cap.
Exhaust screen
Wait for exhaust to cool.
Exhaust screen may be blocked up with carbon deposits.
Undo the screw cap and remove the exhaust screen.
Clean the screen with a wire brush and refit.
Replace exhaust screen if damaged.

Air filter cleaning

Remove the air filter cover (9).
Remove filter element and wash thoroughly in solvent.
Pour a small amount of oil onto the filter element and gently squeeze out any
excess oil.
Replace the filter element and air filter cover.
Be sure the filter cover seals properly all around.
Do not run the engine without the air filter element in place.
Never place a wet filter (with solvent) on the machine.
AFTER SALES SUPPORT