Series Recording Using 2 Or More Vr-716 Recorders; Activation Of Recording Via External Signals - JVC VR-716E Instructions Manual

Jvc digital video recorder instructions
Table of Contents

Advertisement

Series Recording Using 2 or More VR-716 Recorders

Recording using 2 or more VR-716 recorders is possible. Once the first VR-716 is full, recording automatically starts at the second
VR-716.
<VR-716 1>
AUDIO IN
1
2
3
4
5
6
VIDEO IN
THRU OUT
SCSI
AUDIO OUT
VIDEO OUT
LAN
1
2
1
RS-232C
UPS
AUDIO IN
Camera 1
1
2
3
4
5
6
VIDEO IN
THRU OUT
SCSI
AUDIO OUT
VIDEO OUT
LAN
1
2
1
RS-232C
UPS
<VR-716 2>
Camera 16
<Signal Input/Output Terminals>
1
3
5
7
9
11
13
15
RST
COM
IN
IN
CLK
SER
2
4
6
8
10
12
14
16
OUT
RST
REC
WAR
ALARM
OUT
OUT
OUT
[CLOCK RESET OUT]
[CLOCK RESET IN]
1
3
5
7
9
11
13
15
RST
COM
IN
IN
CLK
SER
2
4
6
8
10
12
14
16
OUT
WAR
RST
REC
ALARM
OUT
OUT
OUT

Activation of Recording Via External Signals

While in the Stop mode, recording starts when the [EXT REC IN] terminal at the rear panel receives input signals from external
devices.
1
3
5
7
9
11
2
4
6
8
10
12
ALARM
7
8
9
10
11
12
13
14
15
16
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
2
AVIS:RISQUE DE CHOC
ELECTRIQ
1 4/ 16
5 8
AC IN
(220V–240V )
SIGNAL GND
1
3
5
7
9
11
13
15
RST
COM
IN
IN
EXT REC
CLK
SER
2
4
6
8
10
12
14
16
OUT
9 12
13 16
WAR
RST
REC
COM
ALARM
OUT
OUT
OUT
EE OUT
7
8
9
10
11
12
13
14
15
16
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
2
AVIS:RISQUE DE CHOC
ELECTRIQ
1 4/ 16
5 8
AC IN
(220V–240V )
SIGNAL GND
1
3
5
7
9
11
13
15
RST
COM
IN
IN
EXT REC
CLK
SER
2
4
6
8
10
12
14
16
OUT
WAR
RST
REC
9 12
13 16
COM
ALARM
OUT
OUT
OUT
EE OUT
[COM]
EXT REC
COM
[SERIES REC OUT]
[SERIES REC IN]
[COM]
EXT REC
COM
[EXT REC IN]
13
15
EXT REC
RST
COM
IN
IN
CLK
SER
14
16
OUT
WAR
RST
REC
COM
OUT
OUT
OUT
Connection
<Connection of the Signal Input/Output Terminals>
• Connect the [SERIES REC OUT] terminal at the rear panel of the first VR-
716 to the [SERIES REC IN] terminal of the second.
• Connect the [CLOCK RESET OUT] terminal of the first VR-716 to the
[CLOCK RESET IN] terminal of the second.
• Connect the [COM] terminal of the first VR-716 to the same terminal at the
second.
<Connection between the 2 VR-716 Recorders>
• Connect the [THRU OUT] terminals 1 - 16 of the first VR-716 to the [VIDEO
IN] terminals 1 - 16 of the second VR-716 accordingly.
Setting
• Specify the same settings for both recorders in the "REC MODE" Menu
(☞ Page 24).
• In the "OPERATION" Menu, specify a value other than "NORMAL REC" for
the "RECOVERY REC" item.
• In the "OPERATION" Menu (☞ Page 25) of the first VR-716, set "REPEAT
REC" to "OFF".
• Set the "SERIES REC" item in the "EXT REC" Menu (☞ Page 25) to "ON"
for both recorders.
Notes
• When the [CLOCK RESET OUT/IN] terminals are connected, the clock
in the 2 or more VR-716 recorders will be synchronized twice a day at
12:00 am and 12:00pm.
• Turn off the power of the equipment before connecting.
• Recording at the second VR-716 can only be stopped by using the
[STOP] button on it.
• Recording will not start upon input of signals when the [OPERATE]
button is in the OFF mode.
• Recording will not start when in the Program Timer Standby mode.
• When the power of the first VR-716 is cut off, the second VR-716 starts
recording automatically.
Setting
1.
Set the "EXT REC MODE" item in the "EXT REC"
Menu to "TRIGGER" or "MANUAL".
Notes
• When this is set to "MANUAL", recording is executed only while input
signals are received.
• When this is set to "TRIGGER", recording will continue between the
interval when input signals are received until after execution of the Stop
operation. Recording can only be stopped by using the [STOP] button
on VR-716. Recording cannot be stopped using an external device.
• Recording will not start upon input of signals when the [OPERATE]
button is in the OFF mode.
• Recording will not start when in the Program Timer Standby mode.
61