Xtralis ADPRO Presidium Installation And User Manual
Xtralis ADPRO Presidium Installation And User Manual

Xtralis ADPRO Presidium Installation And User Manual

Adpro presidium intelligent video system installation and user manual
Table of Contents

Advertisement

ADPRO Presidium by
Xtralis
(includes Presidium-Mini)
Installation and

User Manual

March 11, 2010
Part 201975.05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADPRO Presidium and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Xtralis ADPRO Presidium

  • Page 1: User Manual

    ADPRO Presidium by Xtralis (includes Presidium-Mini) Installation and User Manual March 11, 2010 Part 201975.05...
  • Page 3: Fcc Compliance Statement

    Xtralis or its representatives. Total Liability To the fullest extent permitted by law that any limitation or exclusion cannot apply, the total liability of Xtralis in relation to the products is limited to: (i) in the case of services, the cost of having the services supplied again;...
  • Page 4: Radio Interference

    Internal Lithium Battery Caution: The Presidium contains an internal lithium battery. There is danger of explosion if the battery is incorrectly replaced. The battery is not user replaceable and can only be replaced by Xtralis or their Authorised Service Representative. Doc. 12384_05...
  • Page 5 ADPRO Presidium by Xtralis Installation and User Manual Compliance of Power Cord Caution: If the power cord supplied with the Presidium or the Presidium Mini plug pack is not suitable for your local power connection, do not modify the cord or plug pack. Please purchase a power cord that has the safety approvals appropriate for your country.
  • Page 6: Declaration Of Conformity

    Xtralis (UK) Ltd, Vision House, Focus 31, Mark Road Hemel Hempstead Hertfordshire HP2 7BW, UK declares, that the product(s): Product Name: ADPRO Presidium by Xtralis Intelligent Video System Model Number: PDM-xx VM-15 Product Options: Product Name: ADPRO Presidium-Mini Intelligent Video System...
  • Page 7: Table Of Contents

    ADPRO Presidium by Xtralis Installation and User Manual Contents 1 Introduction ............................1 1.1 Features of the Presidium ....................1 1.2 Unique Features of Presidium Mini ...................1 1.3 Installation Steps ........................2 2 Design Guide ............................3 2.1 Introduction .........................3 2.1.1 Purpose ........................3 2.1.2 Scope ........................3...
  • Page 8 Installation and User Manual ADPRO Presidium by Xtralis 2.8 Site Maintenance ....................... 26 2.8.1 Routine Maintenance ..................... 27 2.8.2 Routine Site Maintenance ..................27 2.8.3 Routine Equipment Maintenance ................28 2.8.4 Routine Detection Tests ..................28 2.8.5 Maintenance to Regulatory Requirements ............28 3 Presidium Connectors ........................
  • Page 9 4.6.5 HLI Connection to FastTrace Fails to Operate ............75 4.6.6 Presidium Setup Utility cannot be Started ............. 75 5 Connection to ADPRO FastTrace / FastTx / FastTrace-R by Xtralis .......... 77 5.1 Entering the FastTrace / FastTx / FastTrace-R Setup Screen ........79 5.2 Presidium Inputs .......................
  • Page 10 Installation and User Manual ADPRO Presidium by Xtralis List of Figures Figure 1: Suitable/Unsuitable Perimeter Conditions ................9 Figure 2: Suitable/Unsuitable Area Detection Scenes ................. 10 Figure 3: Required Video Signal ......................11 Figure 4: Camera Dead Zone ......................13 Figure 5: Camera Dead Zone Coverage....................
  • Page 11 ADPRO Presidium by Xtralis Installation and User Manual Figure 56: IP Address Configuration ....................66 Figure 57: Advanced Communication ....................67 Figure 58: High Level Interface ......................67 Figure 59: Security Tab ........................68 Figure 60: Status Tab........................... 69 Figure 61: Presidium Setup Screen ..................... 70 Figure 62: Save to File .........................
  • Page 12 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 13: Introduction

    ADPRO Presidium by Xtralis Installation and User Manual 1 Introduction The Presidium Intelligent Video System is a high performance, modular, multi channel video movement detection system. It is optimised for maximum protection and reliability in the outdoor environment. Presidium Mini is a high performance, DC powered, 2-channel video movement detection system in a desktop/wallmount enclosure for the protection of smaller properties.
  • Page 14: Installation Steps

    Installation and User Manual ADPRO Presidium by Xtralis Installation Steps The following steps must be followed to install a Presidium system: • Design the system Gather site information (refer to Preliminary Information on page 7) Discuss requirements with client Survey the site (refer to Site Survey on page 7) Select the equipment (refer to System Hardware on page 11) •...
  • Page 15: Design Guide

    Installation or configuration of Xtralis’s ADPRO VideoCentral Monitoring Software (refer to Central Monitoring Station Design Guide, Part No: 201700). • Any relevant Application Notes, Tech Tips and FAQs. Refer to Xtralis website - www.xtralis.com. 1.Human-like: a feature that is able to differentiate between human and non-human movement for intru- sion detection.
  • Page 16: Intended Audience

    Installation and User Manual ADPRO Presidium by Xtralis 2.1.3 Intended Audience The intended audience for this Design Guide includes the following key stakeholders: • Security Consultants • System Integrators • System Installers • Facilities / Building / Site Managers 2.1.4 Other Resources A number of other resources should also be used in conjunction with this Design Guide.
  • Page 17: The Role Of Security

    2.3.2 Presidium - an ADPRO Solution ADPRO Presidium and Presidium Mini, in conjunction with the other Xtralis products, are ideally suited for security solutions where the risk is illegal intrusion into a high value asset. The Presidium approach provides reliable protection of a perimeter or sterile area, with rapid identification of the cause of any intrusion within that perimeter.
  • Page 18: Presidium System Concept

    Installation and User Manual ADPRO Presidium by Xtralis Presidium System Concept This section provides a brief description of how Presidium performs image processing to determine if an intruder is present in the protected area. 2.4.1 Operational Concept Presidium analyses video from CCTV cameras to detect movement that is likely to be an intruder.
  • Page 19: Preliminary Information

    ADPRO Presidium by Xtralis Installation and User Manual The system design is critical to ensure that the Presidium system performs as expected. A well- designed system can deliver exceptional performance, whereas a system that has not had a rigorous design process will not perform to expectations. Presidium provides a high level of flexibility in its configuration, but is dependent on the quality of video signals and scene content to deliver a high performance solution.
  • Page 20: Detailed Site Plan

    Installation and User Manual ADPRO Presidium by Xtralis Detailed Site Plan The production of a detailed site plan annotated with key information (refer to Appendix C for an example) is the key element in completing a successful site survey. As a minimum, the following information must be included: Location and type of existing illumination, including coverage, to determine its suitability.
  • Page 21: Figure 1: Suitable/Unsuitable Perimeter Conditions

    ADPRO Presidium by Xtralis Installation and User Manual Figure 1: Suitable/Unsuitable Perimeter Conditions Doc. 12384_05...
  • Page 22: Clarify Requirements

    Installation and User Manual ADPRO Presidium by Xtralis Figure 2: Suitable/Unsuitable Area Detection Scenes Presidium is used in perimeter and area protection scenarios. The key to providing a successful solution is installing Presidium into a scenario that is suited to its requirements. Essentially, the sterility of the area/perimeter to be protected is paramount.
  • Page 23: System Hardware

    ADPRO Presidium by Xtralis Installation and User Manual 2.5.3 System Hardware Appendix D contains a checklist for system design and equipment selection. Camera Selection and Location The selection and location of cameras is vitally important for the successful operation of the Presidium Video Intrusion System.
  • Page 24 Installation and User Manual ADPRO Presidium by Xtralis 2. Camera Field of View (FOV) Setting the correct horizontal FOV of the camera is critical for reliable detection. The horizontal FOV determines the lens required on the camera. The following guidelines are important: •...
  • Page 25: Figure 4: Camera Dead Zone

    ADPRO Presidium by Xtralis Installation and User Manual 4. Dead Zones The dead 'zone' is the area under the camera that the camera cannot view and should be considered during system design. The following figure shows the dead zone area.
  • Page 26: Figure 6: Recommended Presidium Pole Installation

    Installation and User Manual ADPRO Presidium by Xtralis 6. Camera Positioning and Mounting The position and mounting of cameras is vital to ensure reliable performance from a Presidium System. The essentials when choosing a position and mount for cameras are: •...
  • Page 27: Other Detectors Selection And Location

    ADPRO Presidium by Xtralis Installation and User Manual Figure 7: Presidium Pole Front View • Do not install cameras facing at trees or plants, which may move in the wind or drop leaves (tree shadows may also move in the wind). In many circumstances this is unavoidable, but should be limited as far as possible.
  • Page 28: Figure 8: Fov Of Curtain Pir With Camera

    Installation and User Manual ADPRO Presidium by Xtralis The following diagrams illustrate the alignment of a long range PIR with the camera field of view, and a wide angle PIR with the camera FOV. Figure 8: FOV of Curtain PIR with Camera...
  • Page 29: Pir Alignment

    ADPRO Presidium by Xtralis Installation and User Manual The difference in dead zones of the two technologies is an important factor to consider when the PIR/camera combination is used. The PIR may have a very steep downwards angle, whereas a camera may have a much larger dead zone, as illustrated below.
  • Page 30: Pir Termination

    Installation and User Manual ADPRO Presidium by Xtralis Figure 13: PIR Alignment on Fenceline PIR Termination If PIRs are being used on the site, then their detection curtain must be terminated suitably, in a similar fashion to blocking out lights from nearby roads. Referring to Figure 15 under the PIR alignment section, the detection curtain should be terminated by a suitable material at the boundary of detection.
  • Page 31: Camera/Pir Alignment

    ADPRO Presidium by Xtralis Installation and User Manual Camera/PIR Alignment The camera alignment relative to the boundary and other cameras is paramount in ensuring that there are no 'blind-spots' on the site. Align each camera to cover the dead zone of the next camera, and to adequately cover the area under protection.
  • Page 32: Equipment Room

    Installation and User Manual ADPRO Presidium by Xtralis The following are some key considerations in determining the best illumination method: • The requirements will dictate if IR illuminators or visible lighting is used. The cameras used with IR illuminators must be either B&W or day/night cameras capable of automatically switching between colour/B&W depending on the conditions.
  • Page 33: Monitoring Equipment

    ADPRO Presidium by Xtralis Installation and User Manual Environmental Requirements The equipment room should meet the following environmental specification: • Temperature: 0°C (32°F) to 40°C (104°F) - standard Presidium • Temperature: 0°C (32°F) to 40°C (104°F) - Presidium Mini •...
  • Page 34: System Installation

    Installation and User Manual ADPRO Presidium by Xtralis transmitters are optimised for operation over low-bandwidth links, however they also provide outstanding operation over higher bandwidth links. Figure 17: Typical Connections to a standard Presidium System Installation Install the Presidium system and associated hardware in accordance with appropriate CCTV installation practices.
  • Page 35: Installation Hints

    ADPRO Presidium by Xtralis Installation and User Manual Installation Hints When installing cameras in camera housings, the following hints will avert some nuisance alarms. • The application of insect repellent material such as pest control strips or surface spray reduces any nuisance alarms caused by insects or spiders in or near camera housings.
  • Page 36: Instrument Racks And Cablings

    Installation and User Manual ADPRO Presidium by Xtralis Figure 18: PIR Alignment on Fenceline It is important that the PIR curtain is aligned approx 0.5m (2ft) inside the fence when a long range PIR is used next to a fence line (the previous figure illustrates this). The PIR can be aligned using previously described methods.
  • Page 37: Site Commissioning

    ADPRO Presidium by Xtralis Installation and User Manual Site Commissioning The Commissioning Phase consists of the following steps: • Presidium Configuration • Detection Tests • Soak Tests • Monitoring Tests Appendix F contains a commissioning checklist for each Presidium channel.
  • Page 38: Soak Tests

    Installation and User Manual ADPRO Presidium by Xtralis • Execute tests in each detection area based on the type of intrusion, and where possible differing environmental conditions, e.g. day/night/dusk/dawn. Ensure that the alarm activation is reported as expected at the Presidium system, and also that any third party system triggered from the Presidium system receives an alarm notification.
  • Page 39: Routine Maintenance

    ADPRO Presidium by Xtralis Installation and User Manual 2.8.1 Routine Maintenance On many sites, Presidium will be used in conjunction with other detection technologies. The respective maintenance and testing procedures for the other products should be used in conjunction with this information to ensure overall site security is maintained at the required level.
  • Page 40: Routine Equipment Maintenance

    Regular cleaning of the window on any PRO series PIR. The window should be cleaned with lens cleaner and a lint free cloth. If the window is showing signs of deterioration or peeling, please contact your Xtralis supplier for replacement details. •...
  • Page 41: Presidium Connectors

    ADPRO Presidium by Xtralis Installation and User Manual 3 Presidium Connectors Presidium The standard Presidium is housed in a DIN4194 (Eurocard) standard 3U high subrack unit. It is designed to be mounted horizontally in a standard 19 inch rack. Referring to Figure 19, the Presidium may be configured with the following modules: •...
  • Page 42: Presidium Mini

    Installation and User Manual ADPRO Presidium by Xtralis Presidium Mini Presidium Mini is housed in a metal enclosure suitable for desktop placement or vertical attachment to a wall via two screw-mounting tabs. Important: It is a UL requirement that cabling to a wall mounted Presidium Mini is only from the side or top.
  • Page 43: Figure 22: Typical Connections To A Standard Presidium

    ADPRO Presidium by Xtralis Installation and User Manual Figure 22: Typical Connections to a standard Presidium Figure 23: Typical Connections to a Presidium Mini Doc. 12384_05...
  • Page 44: Power Connection

    Installation and User Manual ADPRO Presidium by Xtralis Power Connection 3.3.1 Presidium Presidium is designed for 100-240 VAC 50-60Hz operation. It should not share electrical outlets or circuits with devices that may cause significant electrical interference, such as air conditioners or a photocopier.
  • Page 45: Outputs

    ADPRO Presidium by Xtralis Installation and User Manual Figure 24: Connection to the VM15 Video Module In order to synchronise to the incoming video from the camera and to avoid reduced performance of the video movement detection, the following conditions must be met: •...
  • Page 46: Table 2: Video Output Display

    Installation and User Manual ADPRO Presidium by Xtralis The following table details graphics that are displayed on the video outputs: Table 2: Video Output Display Display When Explanation No Video Screen No video detected (refer to No-Video A blue screen is displayed with the No Video...
  • Page 47: Alarm Inputs

    ADPRO Presidium by Xtralis Installation and User Manual Alarm Inputs There are two alarm inputs (one per channel) on each VM15 Video Module and two in total on Presidium Mini. They are labelled ALM A I/P and ALM B I/P.
  • Page 48: Isolation

    Installation and User Manual ADPRO Presidium by Xtralis Figure 26: Alarm and Isolate Input Configuration Isolation Isolation inputs are provided for each video channel: ALM Isolate A and ALM Isolate B. These connections allow individual channels to be isolated (prevented from generating an alarm). This feature is useful in a number of scenarios: •...
  • Page 49: Alarm Outputs

    ADPRO Presidium by Xtralis Installation and User Manual Alarm Outputs There are alarm outputs provided for each video channel on a VM15 module or Presidium Mini and labelled ALM A O/P and ALM B O/P. Alarm outputs may be used to connect the Presidium to third party alarm panels / DVRs etc.
  • Page 50: Access/Secure Input

    Installation and User Manual ADPRO Presidium by Xtralis Figure 29: Pinouts for Presidium Mini I/O connector 3.9.1 Access/Secure Input The Access/Secure input (pin 2) is used to put the Presidium into the Access or Secure state. When in the Access state, alarm triggers are disabled for alarm inputs and VMD, however alarm input tamper, contrast, and no-video triggers are still enabled (unless disabled by the Alarm Isolate).
  • Page 51: Fault Relay

    ADPRO Presidium by Xtralis Installation and User Manual Figure 30: Access/Secure Input Configuration 3.9.2 Fault Relay Presidium has a fault relay, which is a Form C single pole changeover contact, available on pins 3, 4 and 5 of the General Inputs / Outputs connector. The relay has the following behaviour.
  • Page 52: General Alarm Relay Output

    Installation and User Manual ADPRO Presidium by Xtralis 3.9.3 General Alarm Relay Output Pins 6, 7 and 8 contain a Form C single pole changeover contact set. The general alarm relay (GAR) will activate (i.e. the normally open pole will close) if any of the following valid alarms are triggered on any channel of the Presidium: •...
  • Page 53: Status Leds

    ADPRO Presidium by Xtralis Installation and User Manual Table 4: Network Connection Indicators Port Link Status Network Speed LED Displays 10/100/1000 LAN1 Down All LEDs off and LAN 2 ports (on rear panel) 10 Mbps RH Dual coloured speed LED = OFF LH Green Activity LED = LINK/ACTIVITY (ON if link up or flashing if link up and data transfer activity).
  • Page 54 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 55: Installation / Configuration

    Unpacking After unpacking the Presidium, carefully check for any signs of damage. Any damage should be reported to your supplier, or to Xtralis Pty Ltd directly, before the Presidium is installed. Check that the packing carton contains the following items: •...
  • Page 56: Figure 32: Presidium Setup Utility

    Installation and User Manual ADPRO Presidium by Xtralis Select the Presidium button. The following screen will be displayed. Figure 32: Presidium Setup Utility Select Next. The Licence Agreement is displayed. Figure 33: Presidium Licence Agreement Accept the terms of the agreement and select Next. The Destination Folder screen is displayed.
  • Page 57: Configure The Pc Network Connections

    ADPRO Presidium by Xtralis Installation and User Manual Figure 34: Choose Setup Type Select Next to install the Setup Utility in the default folder, or select Browse to specify a different installation location. Select Install. The Presidium Setup Utility commences installation.
  • Page 58: Figure 35: Local Area Connection Properties

    Installation and User Manual ADPRO Presidium by Xtralis Select Properties. The following screen is displayed. Figure 35: Local Area Connection Properties Highlight Internet Protocol (TCP/IP) and select Properties. The following screen is displayed. Figure 36: Internet Protocol Properties Change the PC IP settings to the following: 192.168.1.2 Set the subnet mask address to: 255.255.255.0...
  • Page 59: Configure Presidium

    ADPRO Presidium by Xtralis Installation and User Manual Configure Presidium Once the Presidium Setup Utility has been installed and the PC’s network connection has been configured, use the following procedure to configure the Presidium. 4.4.1 Connect to an Presidium 4.4.1.1 Local Connection Ensure the fan cover is fitted to the front of the Presidium (standard Presidium only) Use the supplied crossover Category 5 Ethernet cable to connect the PC’s network port to...
  • Page 60: Presidium (Standard)

    Installation and User Manual ADPRO Presidium by Xtralis 4.4.1.2 Remote Connection Ensure the fan cover is fitted to the front of the Presidium (standard Presidium only) Use the supplied crossover Category 5 Ethernet cable to connect the PC’s network port to the Setup port on the front panel of the Presidium (Ethernet port on Presidium Mini).
  • Page 61: Presidium Mini

    ADPRO Presidium by Xtralis Installation and User Manual Once the connection to the Presidium is established, the Password screen is displayed (refer to Section 4.4.3) Presidium Mini The Presidium Mini requires connection to two consecutive IP Address on Port Number 80.
  • Page 62: Setup Utility No Activity Timer

    Installation and User Manual ADPRO Presidium by Xtralis 4.4.2 Setup Utility No Activity Timer The Presidium Setup Utility will automatically disconnect the connection to a Presidium if no mouse movement is detected within a 5 minute period. This action is performed to ensure the Presidium’s detection is enabled.
  • Page 63: Figure 42: Select Function

    Installation and User Manual Figure 42: Select Function Select the ADPRO Presidium Setup radio button and select Next. If this is the first time this Presidium has been connected to, the following screen is displayed. Figure 43: Change Video Standard This screen enables PAL or NTSC to be selected as the video standard.
  • Page 64: Figure 44: Presidium Setup

    Installation and User Manual ADPRO Presidium by Xtralis Figure 44: Presidium Setup The Connect button is used to enable a channel to detect alarm conditions. To temporarily disable the use of a camera and any alarms that may be generated by it, the Disconnect button is used.
  • Page 65: System Status

    ADPRO Presidium by Xtralis Installation and User Manual 4.4.4 System Status The status of the Access/Secure input, Alarm Inputs and Isolation Input can be determined through the Setup Utility GUI. Status information may be useful while commissioning or fault finding a Presidium.
  • Page 66: Configure Channels

    Installation and User Manual ADPRO Presidium by Xtralis 4.4.5 Configure Channels Configuring the channels enables cameras, detection areas and alarm behaviour to be defined. General Setup Highlight the required channel and select Configure. The following screen is displayed. Figure 45: General Tab Channel Name Enter a name for this channel.
  • Page 67: Figure 46: Contrast Level Indicator

    ADPRO Presidium by Xtralis Installation and User Manual Figure 46: Contrast Level Indicator The contrast level indicator shows the dynamic range of the video on the current channel, with black level at the base and peak white at the top.
  • Page 68: Camera Calibration

    Installation and User Manual ADPRO Presidium by Xtralis Camera Calibration Camera calibration calibrates the dimensions and depth of field of the camera’s field of view. Camera calibration is important to ensure that Presidium can accurately determine target sizes. The detection areas and detection parameters are defined in the following sections.
  • Page 69: Areas

    ADPRO Presidium by Xtralis Installation and User Manual Areas Defining the “detection” and “trigger” areas for a camera determines which areas of a camera’s field of view will generate a motion detection alarm. To reduce false alarms, areas of a camera view that contain trees, roads etc should, if possible, be excluded from detection or trigger areas.
  • Page 70: Trigger Area Properties

    Installation and User Manual ADPRO Presidium by Xtralis Trigger Area Properties Figure 49: Trigger Area Properties Trigger Areas can be given a unique Name to assist with identification. Attached to each trigger area are options to: Detect Appearance: Select this option if an alarm is to be generated when a target appears, but has not entered the trigger area by crossing an edge.
  • Page 71: Figure 50: Alarm Logic

    ADPRO Presidium by Xtralis Installation and User Manual The following figure defines the Logic used to generate VMD alarms. It is important to note that Trigger Areas require 2 events before an alarm is generated. Figure 50: Alarm Logic Doc. 12384_05...
  • Page 72: Detection Parameters

    Installation and User Manual ADPRO Presidium by Xtralis Once all required areas have been defined, select the Next button. The following screen is displayed. Figure 51: Detection Parameters Detection Parameters The Detection Parameters enables the detection sensitivity of the Presidium channels to be adjusted.
  • Page 73: Figure 52: Customise Detection Sensitivity

    ADPRO Presidium by Xtralis Installation and User Manual If a cluttered background scene is unavoidable, it is recommended that motion detection be combined with another method of alarm generation (e.g. PIR, microwave detector or fence sensor). Both motion detection AND the alarm input must be triggered before an alarm is generated.
  • Page 74: Table 5: Video Motion Thresholds Explanation

    Installation and User Manual ADPRO Presidium by Xtralis To create a customised sensitivity level: Highlight the sensitivity level on which the new level is to be based. Select New Sensitivity. Enter a name for the new sensitivity level and select OK.
  • Page 75: Alarm Behaviour

    ADPRO Presidium by Xtralis Installation and User Manual Note: The above thresholds may also be displayed in feet (depending on the selection made in Camera Calibration / Display Units). Once the Detection Parameters have been defined, select Next. The following screen is displayed.
  • Page 76 Installation and User Manual ADPRO Presidium by Xtralis VMD (Video Motion Detection) Select the required Hold Time for the VMD. See the explanation of Hold Time above. Alarm Generation An alarm may be generated when an alarm input OR VMD is triggered; or alternatively, when an alarm input AND VMD is triggered.
  • Page 77: Video Monitoring

    ADPRO Presidium by Xtralis Installation and User Manual Figure 54: Video Monitoring Video Monitoring Video Monitoring enables the generation of an alarm when the video signal is tampered with or a camera develops a fault. Contrast Monitoring The Contrast Monitoring feature is provided as a check that the contrast of the camera image is acceptable.
  • Page 78: Network Tab

    FastTrace / FastTx / FastTrace-R, must be entered, (refer to Connection to ADPRO FastTrace / FastTx / FastTrace-R by Xtralis on page 77 for more details). Select the Configure... button to display the IP Address Configuration screen.
  • Page 79: High Level Interface Tab

    FastTx / FastTrace-R. Do not change this setting unless instructed by Xtralis technical support. Figure 58: High Level Interface Refer to the High Level Interface Manual (available on the website: www.xtralis.com/adpro) for details of the Presidium HLI operation. Doc. 12384_05...
  • Page 80: Security Tab

    Installation and User Manual ADPRO Presidium by Xtralis 4.4.8 Security Tab Figure 59: Security Tab Access/Secure Input Type The Access/Secure input allows the Presidium to be independently set into the Access state of operation. This input is usually connected to an alarm panel or access control system.
  • Page 81: Default Settings

    ADPRO Presidium by Xtralis Installation and User Manual Default Settings The Default All Settings button resets the channel, password and network settings. It also disconnects the Presidium. Note: To reconnect to the Presidium, it may be necessary to change the PC network settings, if the Presidium network settings have been previously modified.
  • Page 82: Figure 61: Presidium Setup Screen

    Installation and User Manual ADPRO Presidium by Xtralis Figure 61: Presidium Setup Screen Figure 62: Save to File This enables the complete configuration to be saved. This may then be reloaded in the case of a system malfunction or used to configure another system.
  • Page 83: Loading A Configuration From File

    ADPRO Presidium by Xtralis Installation and User Manual 4.5.2 Loading a Configuration from File Selecting the Load from File button displays the Load Settings from File window. Figure 63: Load Settings from File Navigate to the required .settings file and select Open.
  • Page 84: Upgrading Presidium Software

    ADPRO Presidium by Xtralis 4.5.4 Upgrading Presidium Software Ensure the Presidium Setup Utility is first upgraded to the latest version (refer to the Xtralis web site). The latest version of the Setup Utility is available on the website: www.xtralis.com/adpro Important: Do not upgrade the Presidium software to Version 2 or greater with a Setup Utility V1.xx as this process may leave the unit in a state whereby...
  • Page 85: Troubleshooting

    ADPRO Presidium by Xtralis Installation and User Manual Troubleshooting 4.6.1 Detection Problems Troubleshooting may be performed using a video monitor connected to the Presidium video output, if required. If detection is not occurring as expected, check the following: • Ensure that Camera Calibration has been properly performed (refer to Camera Calibration on page 56).
  • Page 86: Presidium Does Not Appear In List Of Local Units

    Installation and User Manual ADPRO Presidium by Xtralis Select the System Info button to display the Presidium’s IP address and subnet. Presidium Does Not Appear in List of Local Units If the Presidium does not appear in the list of local units: Ensure that the connected PC has a compatible IP Address.
  • Page 87: Hli Connection To Fasttrace Fails To Operate

    Note: Presidium Mini uses an internal hardware jumper to reset the unit to its factory default password. Contact your local Xtralis representative for details. 4.6.5 HLI Connection to FastTrace Fails to Operate Ensure the IP Address and Port Number programmed within the Presidium High Level Interface (HLI) match the respective details within the FastTrace.
  • Page 88 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 89: Connection To Adpro Fasttrace / Fasttx / Fasttrace-R By Xtralis

    ADPRO Presidium by Xtralis Installation and User Manual 5 Connection to ADPRO FastTrace / FastTx / FastTrace-R by Xtralis Figure 68: Complete standard Presidium Installation Doc. 12384_05...
  • Page 90: Figure 69: Typical Connections To A Standard Presidium

    Installation and User Manual ADPRO Presidium by Xtralis Figure 69: Typical Connections to a standard Presidium Note: Before connecting the FastTrace / FastTx / FastTrace-R to the Presidium, ensure the Presidium setup has been completed, refer to Configure Presidium on page 47.
  • Page 91: Entering The Fasttrace / Fasttx / Fasttrace-R Setup Screen

    ADPRO Presidium by Xtralis Installation and User Manual Entering the FastTrace / FastTx / FastTrace-R Setup Screen Remote programming of ADPRO video transmitters is carried out via a screen as shown below. To start the programming operation, connect to the attached FastTrace / FastTx / FastTrace-R...
  • Page 92: Presidium Inputs

    Installation and User Manual ADPRO Presidium by Xtralis Presidium Inputs Note: At least one Presidium Input must be configured. If there are no inputs configured, the following Presidium system alarms will not work at the FastTrace / FastTx / FastTrace-R:...
  • Page 93: Presidium Input Settings

    ADPRO Presidium by Xtralis Installation and User Manual 5.2.1 Presidium Input Settings Highlight the required channel and select the Configure button to setup the Presidium Inputs. Figure 74: Presidium Input Settings Presidium Input Name Option: 16 characters maximum. Enter the name to be associated with this Presidium Input.
  • Page 94: Advanced Communication Properties

    Installation and User Manual ADPRO Presidium by Xtralis Figure 75: Mapping the camera inputs. Advanced Communication Properties Warning: It should not be necessary to change the port number on which the Presidium High Level Interface communicates with the FastTrace / FastTx / FastTrace-R.
  • Page 95: Presidium High Level Interface Properties

    ADPRO Presidium by Xtralis Installation and User Manual Figure 77: Advanced Communication Properties 5.3.1 Presidium High Level Interface Properties When a Presidium is connected to the FastTrace / FastTx / FastTrace-R, the Listener Port Number defines on which port the Presidium High Level Interface communicates with the FastTrace / FastTx / FastTrace-R.
  • Page 96 Installation and User Manual ADPRO Presidium by Xtralis Example IP Addresses: • If the FastTrace / FastTx / FastTrace-R IP address is 192.168.5.10, and the subnet mask is 255.255.255.0, a compatible Presidium IP address would be anything starting with 192.168.5.x (e.g. 192.168.5.11). The Presidium subnet mask should then be set to 255.255.255.0.
  • Page 97: Connection To A Third-Party Dvr

    ADPRO Presidium by Xtralis Installation and User Manual 6 Connection to a Third-Party DVR Figure 78: Typical Connections to a Third Party DVR The above diagram shows a sample configuration for connecting a Presidium to a third-party DVR. The following section describes settings and behaviour associated with the equipment.
  • Page 98 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 99: Adding A Vm15 Module

    Extra VM15 Video Modules may be retro-fitted to provide a maximum of 20 channels per Presidium. Caution: ADPRO Presidium system components contain electrical parts that are susceptible to damage from static discharge. Static voltages of one to thirty kilovolts are common in unprotected environments.
  • Page 100 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 101: Specifications

    ADPRO Presidium by Xtralis Installation and User Manual 8 Specifications Table 6: Presidium Specifications Video Inputs 2 independent camera input per VM15 module or Presidium Mini Each input 1 V peak to peak, 75 ohm or high impedance Video Outputs...
  • Page 102 Installation and User Manual ADPRO Presidium by Xtralis EMC Compliance Emissions: Class A compliance to EN55022:1998 +A1+A2, AS/NZS CISPR 22:2006, FCC Part 15 Harmonic Current Emissions to EN61000-3-2:2000 Voltage Fluctuations & Flicker to EN61000-3-3:1995 +A1 Immunity: EN50130-4:1995 +A1 +A2 (Alarm Systems Product Family Immunity Standard) UPS required for compliance with 100 mS mains voltage interruption requirement applies to Presidium only.
  • Page 103: Appendix A False And Nuisance Alarms

    ADPRO Presidium by Xtralis Installation and User Manual Appendix A: False and Nuisance Alarms Ultimately no security system is perfect, generally through generating false or nuisance alarms. As a security system is made more sensitive to detecting intrusions, the false and nuisance alarm rate can increase.
  • Page 104 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 105: Appendix B Site Survey Checklist

    ADPRO Presidium by Xtralis Installation and User Manual Appendix B: Site Survey Checklist Company_____________________________ Date ___________________ Location _____________________________ Survey by ____________________ Site Plan Annotation Checked Location of lighting Location of equipment room Communications infrastructure identified Trees identified and marked Location of fences and barriers...
  • Page 106 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 107: Appendix C Example Site Plan

    ADPRO Presidium by Xtralis Installation and User Manual Appendix C: Example Site Plan Doc. 12384_05...
  • Page 108 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 109: Appendix D System Design And Equipment Checklist

    ADPRO Presidium by Xtralis Installation and User Manual Appendix D: System Design and Equipment Checklist Company________________________________ Date ___________________ Location ________________________________ Design by ____________________ Channel Camera Lens Field of Lighting Other Camera Cabling Selected Selected View OK Detectors Mounting Distance Any Special Requirements: __________________________________________________...
  • Page 110 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 111: Appendix E Camera / Lens Selection

    ADPRO Presidium by Xtralis Installation and User Manual Appendix E: Camera / Lens Selection Table 7: Horizontal FOV - 20 Metres (66 Feet) Lens 1/4” camera format 1/3” camera format 1/2” camera format focal Max. Distance Dead zone Max. distance Dead zone Max.
  • Page 112: Table 10: Horizontal Fov - 30 Metres (98 Feet)

    Installation and User Manual ADPRO Presidium by Xtralis Table 10: Horizontal FOV - 30 Metres (98 Feet) Lens 1/4” camera format 1/3” camera format 1/2” camera format focal Max. Distance Dead zone Max. distance Dead zone Max. distance Dead zone...
  • Page 113: Appendix F Commissioning Checklist

    ADPRO Presidium by Xtralis Installation and User Manual Appendix F: Commissioning Checklist Company________________________________ Date ___________________ Location ________________________________ Commissioned by ______________ Detection Test Parameters Channel No Detection Test Soak Test Documented Recorded Doc. 12384_05...
  • Page 114 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 115: Appendix G Site Detection Tests

    ADPRO Presidium by Xtralis Installation and User Manual Appendix G:Site Detection Tests Company________________________________ Date ___________________ Location ________________________________ Tested by ____________________ 1. Detection Test Description Test Conditions Detection Area Test (day/night/dusk/ Test Description (Camera Name and No) Number dawn) 2. Detection Test Performance...
  • Page 116 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 117: Appendix H Site Maintenance Tables

    ADPRO Presidium by Xtralis Installation and User Manual Appendix H: Site Maintenance Tables Company_______________________________ Date ___________________ Location________________________________ Maintenance by ____________________ Table 11: Camera Maintenance Table Camera Name and Number Maintenance Due Maintenance Performed Signed Cleaned Window Housing Condition Cable Condition...
  • Page 118 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...
  • Page 119: Appendix I Installation Quick Reference

    ADPRO Presidium by Xtralis Installation and User Manual Appendix I: Installation Quick Reference This appendix provides a quick reference guide for installation of a Presidium system. Camera Alignment Align the camera as described in the site design/plan documentation. Test the alignment by measuring the FOV at the near range and the maximum range.
  • Page 120 Installation and User Manual ADPRO Presidium by Xtralis Maintain System Perform routine maintenance on the system to ensure that detection still occurs as initially planned, and the nuisance alarm rate is at a minimal level. Take remedial action if the system is not functioning as required.
  • Page 121: Appendix J Presidium Do's And Don'ts

    ADPRO Presidium by Xtralis Installation and User Manual Appendix J: Presidium Do’s and Don’ts Don’t Walk test at day/dusk/night Install cameras looking into lights/IR illuminators Trim foliage regularly Change parameters without testing the system Use PIR terminations barriers Use a FOV of greater than 30m (98ft)
  • Page 122 Installation and User Manual ADPRO Presidium by Xtralis Doc. 12384_05...

This manual is also suitable for:

Adpro presidium-mini

Table of Contents