DMX Operation

This section is contains individual DMX channel maps for each luminaire covered in this manual -
VL440 Spot, VL770 Spot, and VL880 Spot. Refer to the corresponding DMX channel map for your
fixture.
VL440 Spot Channel Mapping
VL770 Spot Channel Mapping
VL880 Spot Channel Mapping

Iris Operation

Important Notes and Warnings

Operating fixtures with either Iris 1 or Iris 2 using a software prior to 08/08/12 will cause the iris
to close too far, which will result in damage to the iris and this damage will not be covered under
the warranty.
If iris closes very small, you have an older version of software and MUST update to the software
released 08/08/12 or later.
If iris is not set to the correct iris setting, you will experience the following symptoms:
Iris Installed

Iris Selection / Configuration Operation

This option has been added as described in software technical bulletin LSW-069. LSW-069 Stated
- Installation of this software to all VL440 spot, VL770 spot, and VL880 spot luminaires
manufactured prior to 7/20/12 will be effected that their iris will not close as much as previous
software versions. VL770 spot and VL880 spot luminaires manufactured after 7/20/12 will close
further, but not as far. A long term solution to close the original irises is forthcoming.
All VL440/VL770/VL880 spot luminaires manufactured prior to 07/20/12 and all VL440 spot
luminaires (manufactured prior to and after 07/20/12) are built using iris assembly 22.9687.0230.
These iris assemblies are described in the menu selection as "IRIS 1".
All VL770/VL880 spot luminaires manufactured after 07/20/12 are built using iris assembly
22.9687.0235. These iris assemblies are described in the menu selection as "IRIS 2".
Users now have, in this software release, a menu option to set their fixture to the appropriate iris
setting so all VL440/VL770/VL880 fixtures operate in the same manner during iris opening/
closing operation.
02.96 87.000 1 C
Iris Setting
Iris 1
Iris 2
Iris 2
Iris 1
31 Octo be r 20 13
O
: DMX O
PERATION
Symptom
There will be a delay before the iris will begin to close and
the iris will not close as far.
The iris will not go completely out of the gate.
3