Download Print this page

Troubleshooting - SPX N2 Instruction Manual

Nitrogen generator

Advertisement

nd
2
GENERATION NITROGEN GENERATOR SYSTEM MANUAL

TROUBLESHOOTING

THE FAN OR HEATER IS NOT OPERATING
Confirm that the voltage input to the PTC2 assembly is the correct voltage. Check heater assembly
terminals at the power harness quick-connect plug.
Check wiring harness for cuts or bare insulation.
Confirm fan assembly has not been clogged with debris—clean if necessary.
Nitrogen Generator
with Bottle Back-Up
Shown
Patented 2nd Generation Nitrogen Generator Systems are manufactured and distributed by Waukesha
SPX Transformer Solutions, Inc. U.S. Patent Nos. 6,581,694; 6,568,287; 6,062,821; 5,902,381 and 5,744,764.
Use one or more
N2 Generators
for N2 supply
Regulator
Bypass
Valve set
to "Bypass"
Standard Nitrogen
Generator Shown
Figure 5 – Typical Example of Multiple Transformer Installation
7.5 psi
Mini N2 Shown.
Standard N2 System can be
used with addition of one-way
and isolation valves.
N2-Gen-Manual REV 3.8, 8/2014
®
Service & Components, a division of
For each transformer,
use SPX Waukesha
Part Number MN2-0A0133
TO TRANSFORMER
TO TRANSFORMER
TO TRANSFORMER