SPX N2 Instruction Manual page 7

Nitrogen generator

Advertisement

nd
2
GENERATION NITROGEN GENERATOR SYSTEM MANUAL
INSTALLATION – SINGLE TRANSFORMER
CAUTION:
The unit must be mounted in an upright position. Do not mount unit on its side or
back. The unit MUST be vertical for 12 hours before turning the unit on.
WARNING:
A crane, or similar lifting device, is required to lift and secure unit to wall
mounting surface.
CAUTION:
Do not block the ventilation inlets and outlets as this could cause overheating
and damage to the unit.
WARNING:
Support structure and mounting hardware must be capable of supporting the
generator weight of 380 lbs. minimum. Cabinet is designed to be mounted using 1/2"
hardware.
The unit must be mounted above grade level.
Install unit away from heat sources.
Do not install in an enclosed cabinet; proper ventilation is required.
Figure 3 – Generator Mounting Dimensions: Standard Generator (left) and Generator with Bottle Back-Up (right)
1) Measure and mark the mounting holes or studs as shown by the center-to-center distances of Figure 3
above. IMPORTANT: Verify the bolt holes are level and high enough to support cabinet above grade.
2) Lift the unit into position with crane and top hook.
3) Secure hardware. NOTE: Cabinet is designed to be installed using 1/2" hardware.
4) Plumb to transformer using copper or stainless steel 1/4" or larger tubing. NOTE: Inlet and outlet ports
of generator are female 1/4" NPT.
Patented 2nd Generation Nitrogen Generator Systems are manufactured and distributed by Waukesha
SPX Transformer Solutions, Inc. U.S. Patent Nos. 6,581,694; 6,568,287; 6,062,821; 5,902,381 and 5,744,764.
N2-Gen-Manual REV 3.8, 8/2014
®