GENERATION NITROGEN GENERATOR SYSTEM MANUAL
TROUBLESHOOTING
COMPRESSOR DOES
NOT OPERATE
MEMBRANE PRESSURE
OR DELIVERY PRESSURE
TOO LOW (CONTINUOUS
RUN) OR GENERATOR
SHUTDOWN ON BOTTLE
BACK-UP SYSTEM
DESIRED NITROGEN
FLOW NOT ACHIEVED
* To check for leaks, use soap solution of leak-tracing spray.
Patented 2nd Generation Nitrogen Generator Systems are manufactured and distributed by Waukesha
SPX Transformer Solutions, Inc. U.S. Patent Nos. 6,581,694; 6,568,287; 6,062,821; 5,902,381 and 5,744,764.
Power source is off
Unit is in "Standby"
status
Temperature is too high
or low
Inlet filter is contaminated
Leaks in the hoses or
connections
Excessive consumption
Pressure switch
mis-adjusted
Coalescing filter(s) dirty
or bowls are leaking
One way valve leaking
Leaks in hoses or
connections
Climate control not
working
Turn main power source on
Wait until pressure in storage
vessel is reduced
Ambient temperature is too high
(above 40°C)
Climate control is not functioning
properly and should be checked
Call SPX Waukesha
Replace the carbon filter and
compressor inlet filter
Seal any leaks*
Contact SPX Waukesha to
confirm appropriate application
Set pressure switch
Replace filters and check bowls
for leaks*
Replace the one-way valve
Seal any leaks*
Call SPX Waukesha
N2-Gen-Manual REV 3.8, 8/2014
®
Service & Components, a division of
22