GENERATION NITROGEN GENERATOR SYSTEM MANUAL
CLIMATE CONTROL (continued)
Press the "3 Select" button to continue. The alarm LED will flash and the display will show "ALL", indicating
the "ALL" alarm on/off status. Press "3 Select" and the display will show either "ON" or "OFF", indicating
current alarm status. Press "1 Adjust-up" or "2 Adjust-down" to toggle the mode as desired. If the "OFF"
mode is selected, no alarms will activate and the audible on/off select function is skipped.
Press the "3 Select" button to continue. The audible LED will flash and the display will show "AUD",
indicating the audible alarm on/off status. Press "3 Select" and the display shows "ON" or "OFF" indicating
the current audible alarm status. Press "1 Adjust-up" or "2 Adjust-down" arrow to toggle the mode
desired.
Press the "3 Select" button to continue. The "C" LED flashes and the display shows either "F" for degrees
Fahrenheit or "C" for degrees Celsius. Press the "1 Adjust-up" arrow or "2 Adjust-down" arrow to toggle
the mode as desired.
Press the "3 Select" button to continue. The code LED is on and the display shows "PIN". To set a new
user PIN code, press the "1 Adjust-up" button. The display will flash "4", prompting an entry of a four button
sequence using the "1 Adjust-up", "2 Adjust-down", "3 Select" and/or "4 Exit" buttons. Any sequence
of the four buttons may be programmed as the code. As the buttons are pressed, the display will show the
number of buttons that were pressed.
NOTE: After pressing a button, there will only be 5 seconds to press the next button. If the next button is not
pressed within the allotted time, the system will default to no PIN code, indicated by "0" on the display. Once
the sequence is entered the display will no longer flash, and will show "4".
CAUTION
Always record the selection sequence (PIN code) and store in a secure place.
Press the "3 Select" button to continue. The filter LED flashes and the display will show "FIL", indicating the
filter alarm DAYS selection. Press the "3 Select" button and the display will show the number of days that
the alarm is set in one-half day increments. Example: 10.5 indicates the alarm will activate every ten and
one-half days.
Press the "1 Adjust-up" or the "2 Adjust-down" arrow to vary the desired number of days. Programming 0
days will disable the alarm.
NOTE: The required number of days to set this alarm will be determined by the ambient air
conditions.
N2-Gen-Manual REV 3.8, 8/2014
®