Ez Connect - Rinnai REU-KM3237FFUD-E Installation And User Manual

Continuous flow water heater
Hide thumbs Also See for REU-KM3237FFUD-E:
Table of Contents

Advertisement

NEW FEATURE
Installing the EZ Connect
1.
Install the two Infinity water heaters from 50mm to 450mm apart so that the EZ
Connect cable will reach between the two.
More than 450mm apart can cause temperature fluctuations.
2.
Remove the protective cap from the 3 pin connector marked EZ Connect located in
the wiring harness of the Primary Unit (Fig. 1)
Fig.1
Fig.2
3.
Plug in the EZ Connect cable. The end marked To EZ Connect connects in the
primary Infinity water heater to the 3 pin connector seen in Fig. 2. The other end,
marked To PCB, connects to the empty plug at the top of the PCB of the other
water heater (sub unit.) (Fig. 2 and 3)
4.
Securely fasten the EZ Connect cable to the bottom of each Infinity water heater
with the cable clamps and screws supplied. (Fig. 4)
The EZ Connect cannot be
used with the MECS.
The EZ Connect cannot use
the Bath Fill Function
The temperature can only be
NOTE
changed on the primary unit's
controller.
PAM valves are not required.

EZ CONNECT

EZ Connect Installation
The EZ Connect allows the installation of two Infinity water
heaters to be controlled by one remote controller without PAM
valves or a MECS. This will allow temperature control through
use of a single remote, while error messages will be displayed
on the status monitor.
heaters for low flows and rotate the lead heater for even use.
50 -
450mm
35
The EZ Connect will sequence the
Fig.3
Fig. 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reu-km3237wd-eReu-km3237ffudhd-eReu-km3237wdhd-e

Table of Contents