DIAGNOSTICS CYCLE PHASES
Knob
Function
position
tested
Operation of the
display board
1
Water fill to wash
2
compartment
Water fill to pre-wash
3
compartment
Water fill to
4
conditioner
compartment
Hot water fill or fill to
5
bleach compartment
(certain models only)
Heating (and, in
Jetsystem models,
recirculation)
6
Check for leaks from
tub
7
Drain and spin,
check for pressure
8
switch congruency
Drying
(washer/dryers only)
9
If an alarm condition occurs during the course of the diagnostics cycle, the appliance stops and the
display or LEDs flash to indicate the alarm code.
TSE-P 01.01 EB
Components
actioned
All the LEDs light in
sequence. When a
button is pressed, the
corresponding LED
lights
- door interlock
- wash solenoid
- door interlock
- pre-wash solenoid
- door interlock
- pre-wash solenoid
- wash solenoid
- door interlock
- hot water or bleach
solenoid
- door interlock
- (wash solenoid if
level is lower than the
antiboiling device)
- recirculation pump
(Jetsystem models)
- heating element
- door interlock
- (wash solenoid if
level is <150mm)
- motor
- door interlock
- drain pump
- motor
- door interlock
- drain pump
- drying heater (full
power)
- fan motor
- condensation
solenoid
40/56
Operating
conditions
Always operative
Door closed, water fill to anti-
overflow level for max. 10 min
Door closed, water fill to anti-
overflow level for max. 10 min
Door closed, water fill to anti-
overflow level for max. 10 min
Door closed, water fill to anti-
overflow level for max. 10 min
Door closed, water fill to above
anti-boiling level if not yet
reached, heating for max. 10
min or to 90°C
Door closed, water fill above
150mm level if not yet
reached, motor until the drum
reaches 250 rpm
Door closed, water drain,
motor movement, until
maximum spin speed is
reached
Door closed, water drain to a
level lower than the anti-boiling
device, drying heater for max.
10 min or until the drying
temperature sensor (fitted to
the duct) detects a
temperature of 150°C
Parameters
displayed
Button code
Water level in
mm
Water level in
mm
Water level in
mm
Water level in
mm
Water
temperature in
°C
Motor speed
(rpm)
Motor speed
(rpm ÷ 10)
NTC drying
temperature
and condenser
temperature
(°C, displayed
alternately for
2 sec)
599 34 55-61