    4.1 Special conditions for use in explosive areas 19 Safety precautions Ex-Data Technical specifications Functional description / operating instructions 8.1 Assembly of the Lite-Ex PL 10 8.2 Getting started 8.3 Battery replacement 8.4 Cleaning the ring switch 8.5 LED replacement 8.6 Replacing the protective disc 8.7 Assembling the belt clip...
  • Page 3: Application

    1. Application The Lite-Ex PL 10 is a compact, robust and easy-to-use LED flashlight for industrial applica- tion in Ex-hazardous areas classified as Zone 2, 1 and 0, as well as Zone 22, 21 and 20, in ac- cordance with directive 1999/92/EC (ATEX 137).
  • Page 4: Safety Regulations

    - unit markings or inscriptions are illegible. - malfunctions occur. - permitted limit values have been exceeded. 4. Safety regulations Use of this unit assumes that the operator obser- ves the conventional safety regulations and has read the certificate in order to eliminate faulty operation of the unit.
  • Page 5: Safety Precautions

    5. Safety precautions Risk of blinding! - Do not look directly into the light beam - Do not aim the light directly into the eyes of another person 6. Ex-Data EC type approval test certificate no.: ZELM 05 ATEX 0272 X Ex-designation: II 1G Ex ia op is IIC T4 Ga II 1D Ex ia IIIC T130 °C Da...
  • Page 6: Technical Specifications

    7. Technical specifications Ambient temperature Ta: -20 °C ... +50 °C Storage temperature: -30 °C ... +60 °C Batteries / power supply: 3 x LR03 according to IEC, AAA Lamp: High performance LED: 3000 lx Operating time: 1200 lx after 3 hours, approx.
  • Page 7: Functional Description / Operating Instructions

    Please read these operating instructions care- fully so that you are familiar with, and are able to use, all of the functions of your Lite-Ex PL 10. For your own safety and informa- tion please read the instructions on the following pages carefully! 8.1 Assembly of the Lite-Ex PL 10...
  • Page 8: Battery Replacement

    8.4 Cleaning the ring switch A non-contacting ring switch is used to switch on the Lite-Ex PL 10 (see description above). Dirt and moisture do not impair the switching func- tion. The ring switch is easy to clean if excessive amounts of dirt and grime have made it difficult to turn.
  • Page 9: Led Replacement

    Should, however, the disc break, it is possible to replace it. To do this grasp the body of the Lite-Ex PL 10 and the ring switch and then carefully unscrew the lamp head by turning it anti-clockwise. To unscrew the lamp head from the LED housing use an Allen key (AF4) to secure the LED housing in place (see Fig.
  • Page 10: Assembling The Belt Clip

    ring is set in a groove under the protective disc). When replacing the lamp head on the LED housing make sure the seal and disc are seated properly. After assembly no part of the seal should be visible through the opening where the beam is emitted.
  • Page 11: Repair

    European Directive 2002/96/EC and the German electrical law of 16/03/2005. The costs associ- ated with returning devices to ecom instruments GmbH are to be borne by the sender. In accordance with Article 1, Section 18 and...
  • Page 12: Cleaning, Maintenance And Storage

    hazard and can cause chemical injuries if it is used improperly. Neither the battery nor the battery cells should be opened or disassembled and they should not be burned or exposed to temperatures exceeding 100 °C. If the battery needs to be disposed of, it can be removed as described under point 8.3.
  • Page 13: Warranty And Liability

    GmbH assumes no liability for special, direct, indirect, accompanying or con- sequential damage as well as losses including...
  • Page 14 tioned limitations and exclusions are not valid for every purchaser. Should any such clause of these warranty conditions be declared ineffective or unenforceable by a competent court, then the effectiveness or enforceability of any of the other conditions of these warranty conditions shall remain unaffected by such a judgement.
  • Page 15: Ec Declaration Of Conformity

    Declaration of EC-Conformity according to directive 94/9/EC (ATEX) We ecom instruments GmbH, declare under our sole responsibility, that the product to which this declaration relates, is in accor- dance with the provision of the following standards, directives and norms: name & adress of manufacturer in the EC ecom instruments GmbH Industriestraße 2...
  • Page 16: Ec-Type Examination Certificate

    14. EC-Type Examination Certificate 1) The following special conditions according to the EC type approval test certificate must be observed: Opening the housing within the explosive area is not permitted. 1. The installed batteries may only be exchanged outside the explosive area and only by those types approved by the manufacturer.
  • Page 17 Garantie der Markttauglichkeit und der Eignung für einen bestimmten Zweck, es sei denn, anwendbare Gesetze oder Rechtsprechungen schreiben zwingend eine Haftung vor. Die ecom instruments GmbH behält sich das Recht vor, jederzeit ohne vorhergie Ankündigung Änderungen an diesem Dokument vorzunehmen oder das Dokument zurückzuziehen.