Advantage MicroTron Installation Manual

Timer controller

Advertisement

Quick Links

MicroTron
Timer Controller
Installation
Maintenance
Repair
Manual
Advantage Controls
P.O.Box 472
Muskogee, OK 74402
Phone: 800-743-743
Fax: 888-686-622
www.advantagecontrols.com
Manual

HE-22
/08

Advertisement

Table of Contents
loading

Summary of Contents for Advantage MicroTron

  • Page 1 Manual MicroTron Timer Controller Installation Maintenance Repair Manual Advantage Controls P.O.Box 472 Muskogee, OK 74402 Phone: 800-743-743 Fax: 888-686-622 www.advantagecontrols.com HE-22 /08...
  • Page 2: Table Of Contents

    MicroTron Timer Controller Instruction & Maintenance Manual Table of Contents Contents Page No. I. Introduction ..................3 Model Numbering ................3 II. Description ..................3 III. Installation Electrical Wiring ................4 Conduit Layout for LCD Display ............4 Mounting Instructions ..............5 Typical Installations .................
  • Page 3: Introduction

    Model Numbering MicroTron timer controllers have several base functions and optional features available. Your unit may be supplied with one or more of the options that are described in this manual. To determine what features apply to your unit, check the model number label located on the controller enclosure.
  • Page 4: Installation

    Installation Electrical Wiring The standard MicroTron Timer controller has an internal regulated power supply that will operate in the range of approximately 90 to 240 VAC on the incoming wiring. Output relay(s) are protected with a replaceable fuse. Relay output voltage will equal the incoming line voltage.
  • Page 5: Mounting Instructions

    Mounting Instructions Select a mounting location that provides the operator easy access to the unit and a clear view of the controls through the cover of the controller. The unit should be located convenient to grounded electrical connections, the required sample line plumbing, and installed on a stable vertical surface. WARNING: Avoid locations that expose the controller to direct sunlight, vapors, vibration, liquid spills or extreme temperatures;...
  • Page 6: Front Panel Description

    Front Panel Drawing Front Panel Description x6 character display. READ: Relay , Relay 2, Relay 3, Relay 4 - HOA switches for control relays. CONTROL: KEY PAD SET UP/RUN KEY - System initializes into RUN mode. Press this button key to toggle SET UP/ the controller from SET UP mode to RUN mode.
  • Page 7: System Operation Overview

    System Operation Overview MicroTron controllers have two modes of operation, RUN and SET-UP. Both the RUN and SET UP menus are circular. Pressing the DOWN key in either menu will display the next line of information on the display. After the last item in a menu has been displayed, pressing the DOWN key will return the display to the top line of that menu.
  • Page 8: Chem Feed Set

    -- CHEM FEED SET-- CHEM FEED SET Units with selectable feed timer(s) will have this SET ENTER Shows timer currently selected UP menu for selecting the chemical feed method and setting the feed time. A selectable feed timer can be programmed as one of the following: ENTER To change to a different timer.
  • Page 9: Biocide Set

    BIOCIDE SET --BIOCIDE SET-- ENTER Shows BIO A timer  activation day Units with a biocide timer will have this SET UP menu for setting biocide feed times. The Biocide Set Menu ENTER To change day of the week consists of two weekdays, week and start times and To cycle through day options one feed length time and lockout setting for each SUN,MON,TUES,WED,THUR,FRI,SAT,...
  • Page 10: Clock Set

    --CLOCK SET-- CLOCK SET The CLOCK SET menu is for adjusting the time, SET TIME XX.XX.XX (hh.mm.ss) ENTER date and day of the week. After entering a new value, hit the ENTER key To change clock setting CLEAR to accept the value. The clock time is based on a 24 hour clock.
  • Page 11: System Set Menu

    --SYSTEM SET-- SYSTEM SET MENU This menu is used to configure the controller to PASSWORD XXXX ENTER specific operational needs. Some of the items in this menu may not apply depending on the controller model but will always be present. ENTER To change password PASSWORD - If a value of 0000 is entered,...
  • Page 12 SYSTEM SET MENU (Continued) Scroll to choose baud rate FLOW WHEN CLOSED - For flow switches. FLOW ALARM - With FLOW ALARM ON, when ENTER To accept change the system loses flow, an alarm signal can be sent. FLOW ALARM OFF means that no alarm signal is sent in the event of loss of system flow.
  • Page 13: Diagnostics Menu

    --DIAGNOSTICS-- DIAGNOSTICS MENU This menu is used to select, enter and test the following items. MODEL # LF-2B-2 MODEL NUMBER - Read only screen. SOFTWARE V.(n) SOFTWARE VERSION NUMBER - Read only screen. Please have this number if calling for support.
  • Page 14: Run Menu

    WATER METER If a water meter is being used, number of contacts Troubleshooting The Advantage Microtron controller is designed for many years of trouble free operation. Should a problem occur, refer to the following chart to help identify the problem. SYMPTOM...
  • Page 15: Fcc Warning

    VII. Advantage Controls’ Product Warranty Manufacturer’s Product Warranty Advantage Controls warrants control systems of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 24 months from date of installation. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer’s examination.
  • Page 16 Get the Advantage in Water Treatment Equipment Advantage Controls can give you the Advantage in products, knowledge and support on all of your water treatment equipment needs.  Cooling Tower Controllers  Boiler Blow Down Controllers  Blow Down Valve Packages  Solenoid Valves...