Bearing sensor
Atmospheric
pressure/altitude
sensor
Atmospheric
pressure
Altitude
Depth
Waterproof
performance
Crash resistance
perfomance
Withstand Load
Performance
Dustproof
performance
16 bearing detection (with angular position correction
function by the 3 axes acceleration sensor, with automatic
declination correction, and with automatic offset adjustment
function)
Measurement range 300 hPa to 1100 hPa, with 24 hour
memory function in 1 hPa unit (every 1.5 hours)
Convert atmospheric pressure to altitude using ISA
[International Standard Atmosphere],
accuracy: j5 m to i5 m
Displays in 3 levels (displays 0 m to 13 m in 3 levels)
Equivalent to IEC 60529 "IPX8".
(Usable for 60 minutes in 13 m water depth)
The test method of the camera is in compliance with
"MIL-STD 810F Method 516.5-Shock"
"MIL-STD 810F Method 516.5-Shock" is the test method
¢
standard of the U.S. Defense Department, which specifies
performing drop tests from a height of 122 cm, at
26 orientations (8 corners, 12 ridges, 6 faces) using 5 sets of
devices, and passing the 26 orientation drops within
5 devices.
(If failure occurs during the test, a new set is used to pass the
drop orientation test within a total of 5 devices)
Panasonic's test method is based on the above "MIL-STD 810F
Method 516.5-Shock". However, the drop height was changed
from 122 cm to 200 cm dropping onto 3 cm thick plyboard. This
drop test was passed.
(Disregarding appearance change such as loss of paint or
distortion of the part where drop impact is applied.)
There is no guarantee of not breaking or malfunctioning
under all conditions.
100 kgf (According to the test conditions specified by
Panasonic)
Equivalent to IEC 60529 "IP6X".
¢
.