Installation Manual
INSTALLATION SEQUENCE OVERVIEW (Continued)
Shown below are schematics of the two typical configurations which utilize the jumper cable.
Wiring to an adjacent luminaire
Step No. 1:
After luminaires have been mounted in place, make the
electrical connections, using the integral quick connect
fittings.
Step No. 2:
Push the connections carefully back into the luminaire
and snap the strain relief fittings into the luminaire.
Step No. 3:
The completed connection
FCLS-Slim Manual 8-11
8020 Queenair Drive, Gaithersburg, MD 20879 USA • phone: 301 921 4120 • fax: 301 963 3050
email: info@CathodeLightingSystems.com • website: www.CathodeLightingSystems.com
Wiring from the luminaire to the branch circuit
Step No. 1:
With one end of the jumper cable attached and
electrically connected to the luminaire, snap the
strain relief into the 1/2" (trade size) pryout in the
junction box
Step No. 2:
Using UL-listed wire connectors, connect:
• the black lead of the jumper cable to the hot
branch ciruit or the hot dimmer lead
• the white lead of the jumper cable to the neutral
branch circuit or neutral dimmer lead
• the green lead of the jumper cable to ground
Page 5