Supplemental Information

Alignment of Yoke Rotation (if needed)

NOTES: X-RAY LEVELS ARE EXTREMELY LOW, HOWEVER WHEN
ALIGHNING THE YOKE THE BEAM LIMIT CURRENT SHOULD BE
KEPT LOW (CONTRAST < 30 ON THE BAR MENU).
DO NOT TOUCH THE WINDINGS OR TERMINALS OF THE
DEFLECTION YOKE. CONTACT WITH THE WINDINGS OR
TERMINALS POSE A SERIOUS SHOCK HAZARD.
To align the new CRT to the other two for minimum converge power and optimize
accuracy, you must readjust the mechanical rotation of the yoke.
NOTE:
required.
MP8 CRT Installation
Reset software for convergence values.
Remove the top white plastic shield.
Turn on the projector and display an internal crosshatch.
Rotate the Deflection Yoke (closest to the front of the CRT) to match the other
setup while looking at the center horizontal lines of a crosshatch.
Place a dab of hot melt on CRT and Yoke to insure that the deflection yoke
does not move.
Reattach the top plastic shield.
Upon completion, a full optical alignment may be